Permit Details

Status:
Final
Type:
DUPLEX NEW
Apply Date:
09/09/2002
Applicant:
TINAJAS BUILDING COMPANY, LLC
Description:
DUPLEX:TD#15-53-34

Outstanding Activity Conditions

Permit Number - T02CM04230
Permit Status: Final
Permit Description: DUPLEX:TD#15-53-34
Total Outstanding Activity Conditions - 1
Date Name
09/09/2002 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T02CM04230
Permit Description: DUPLEX:TD#15-53-34
Total Completed Inspections - 23
Date Description Inspector Results Comments
09/24/2002 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection 0000*
10/02/2002 ELECTRIC - UFER JORTA Approved IVRS - Inspection 0000*
10/07/2002 BUILDING PRE-SLAB AMATHIES Approved IVRS - Inspection 0000*
10/07/2002 EXCAVATION/LAYOUT REBAR & ZON AMATHIES Approved IVRS - Inspection 0000*
10/24/2002 PLUMBING - SEWER HCS CONNECT RMYERS Approved IVRS - Inspection 0000*
10/24/2002 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection 0000*1.) SDR SEWER SHADED OK OK TO COVER WITH NATIVE SOILS 2.) PVC YARDWATER SHADED OK TO COVER NATIVE SOILS.
11/08/2002 FRAMING LHANLY Approved IVRS - Inspection 0000*
11/08/2002 ROOF NAILING LHANLY Approved IVRS - Inspection 0000*
11/08/2002 EXT METAL CLIPS/EXT SHEATHING LHANLY Approved IVRS - Inspection 0000*
11/12/2002 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection 0000*
1.) FOR FINAL AIR HANDLER COMPLETE ELECT. DATA W/PROPER AUX. HT STRIP. PLATE. APT #2 CARRIER A/H. CLEAR BOTH
2.) ACCESS PANEL IN FRONT, REFRIG LINES, GALV. STRAPS, ETC.
3.) REFRIG. LINES DO NOT ALLOW STEEL TO TOUCH COPPER DO NOT NEED LEAKS.
4.) OUTSIDE FRESH AIR? CONSULT 1999. IMC.
11/12/2002 ELECTRIC - INTERMEDIATE DSANTACR Approved IVRS - Inspection 0000*
11/13/2002 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection 0000*
1.) ABS DWV THRU ROOF OK WATER TEST OK
2.) PEX PIPING OK PRESSURE TEST OK
3.) TUBS OK
4.) CLOSET FLANGES OK
5.) OK TO COVER WALLS.
6.) CONTRACTOR WILL HAVE PLUMBER REPLACE NIAL GUARDS ON BOTTOM PLATE WITH FHA STRAPS.
11/22/2002 U VALUE FOR WINDOW LHANLY Approved IVRS - Inspection 0000*
11/22/2002 STUCCO MESH LHANLY Approved IVRS - Inspection 0000*SHEAR WALLS NOT NAILED PER DETAIL
2.) FIRE STOP ALL PENETRATIONS IN FIRE WALL
3.) FIRE STOP REQUIRED ON FIRE WALL WHERE JOINTS EXCEED 1/16" NON - TIGHT CONST.
4.) DO NOT TAPE OR MUD FIRE OR SHEAR WILL UNTIL.
FIRE STOP INSPECTION IS COMPLETE.
11/29/2002 SHEET ROCK NAILING LHANLY Approved IVRS - Inspection 0000*
01/16/2003 ELECTRIC - CABLE DROP DSANTACR Approved IVRS - Inspection 0000*SENT TO TEP 1/17/03 AT 9:15AM OK CABLE DROP ONLY. UNITS 1 & 2
NOTES
1.) PRIOR TO RELEASE OF POWER, A UNSPLICED GROUNDING ELECTROD CONDUCTOR TO BE INSTALLED FROM UFER TERMINATION POINT AT SERVICE #2.
2.) ALSO INSTALL BOND BUSHING AT ALL CONNECTORS WHERE UNPROTECTED CONDUCTORS PASS THRU.
01/23/2003 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection 0000*SENT TO TEP ON 1/24/03 AT 9:15AM OK TO CLEAR OK CABLE DROP. UNITS #1 & 2.
01/23/2003 ELECTRIC - TEMPORARY SERVICE DSANTACR Approved
01/28/2003 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection 0000*
01/28/2003 PLUMBING - FINAL RMYERS Approved IVRS - Inspection 0000*/ 1) PLUMBING FINAL-OK 2) OK FOR C OF O PENDING ANY OTHER INSPECTION
01/31/2003 BUILDING - FINAL AMATHIES Approved IVRS - Inspection 0000*
02/05/2003 PERMIT FINALED AMATHIES Approved
02/05/2003 PLUMBING - GAS PRESSURE TEST RMYERS Approved