Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Apply Date:
08/15/2002
Applicant:
GOLDEN STAR PROPERTIES ,
Description:
SFR:NEW
Contractors:
  • GOLDEN STAR PROPERTIES ,

Outstanding Activity Conditions

Permit Number - T02CM03840
Permit Status: C of o
Permit Description: SFR:NEW
Total Outstanding Activity Conditions - 1
Date Name
08/15/2002 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T02CM03840
Permit Description: SFR:NEW
Total Completed Inspections - 23
Date Description Inspector Results Comments
12/05/2002 PLUMBING - YARD WTR LINE/TEST FGREER Approved
12/05/2002 PLUMBING - ROUGH, SOIL FGREER Approved IVRS - Inspection 0000*
12/05/2002 ELECTRIC - UFER FGREER Approved IVRS - Inspection 0000*
12/05/2002 BUILDING PRE-SLAB FGREER Approved IVRS - Inspection 0000*
12/05/2002 EXCAVATION/LAYOUT REBAR & ZON FGREER Approved IVRS - Inspection 0000*
12/18/2002 ROOF NAILING RFREIDIN Approved IVRS - Inspection 0000*
12/18/2002 EXT METAL CLIPS/EXT SHEATHING RFREIDIN Approved IVRS - Inspection 0000*/ 1) MISSED NAILING AT BEAM OVER TO FRONT WALL AT FRONT DOOR, MARKED IN BLACK 2) INSTALL ALL OSB ON WLLS FOR EXT. CLIP INSP (H2.5'S VERIFIED AT LEDGERS OK TO COVER 3) CROSS MARKED ON GARAGE DECK BROKEN OSB BLOCK BELOW FOR SUPPORT 4) FRONT DOOR PLATE OFF SLAB 5) SEE POST TENSION PLAN ALL CABLES TO BE PULLED BEFORE ROOF SHEATHING IS APPLIED 6) ALL BOLTS FOR H.D.'S TO BE SPECIAL INSPECTED (EPOXY SET)
02/21/2003 MECHANICAL - INTERMEDIATE DBRITO Approved IVRS - Inspection 0000*
02/21/2003 PLUMBING - INTERMEDIATE DBRITO Approved IVRS - Inspection 0000*
03/05/2003 PLUMBING - GAS PRESSURE TEST HPEDROZA Approved IVRS - Inspection 0000*
03/05/2003 ELECTRIC - CONSTRUCTION POWER HPEDROZA Approved IVRS - Inspection 0000*
03/05/2003 ELECTRIC - TEMPORARY SERVICE HPEDROZA Approved IVRS - Inspection 0000*
03/05/2003 ELECTRIC - CABLE DROP HPEDROZA Approved IVRS - Inspection 0000*
03/05/2003 ELECTRIC - INTERMEDIATE HPEDROZA Approved IVRS - Inspection 0000*
03/05/2003 U VALUE FOR WINDOW HPEDROZA Approved IVRS - Inspection 0000*
03/05/2003 FRAMING HPEDROZA Approved IVRS - Inspection 0000*/ 1) VENT AT KITCHEN SINK MUST BE AT A 45 DEGREE 2) OK TO INSULATE
03/18/2003 SHEET ROCK NAILING RFREIDIN Approved IVRS - Inspection 0000*
07/28/2003 MECHANICAL - FINAL RFREIDIN Approved IVRS - Inspection 0000*
07/28/2003 PLUMBING - FINAL RFREIDIN Approved IVRS - Inspection 0000*
07/28/2003 ELECTRIC - FINAL RFREIDIN Approved IVRS - Inspection 0000*
07/28/2003 BUILDING - FINAL RFREIDIN Approved IVRS - Inspection 0000*/ 1) NEED TO HAVE APPROVAL FOR SLOPE, RIP RAD SOIL CONDITION, BY ELIZ. EDER BACK FLOOD PLAIN 2) PLEASE HAVE POST TENSION INSPECTOR LOCK AT GARAGE END OF SLAB AT CABLES (TWO) CONCRETE SURFACE IS CRACKED
05/12/2004 PERMIT FINALED RFREIDIN Approved
05/12/2004 STUCCO MESH RFREIDIN Approved