Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 05/12/2004 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection :* |
| 05/06/2004 |
BUILDING - FINAL |
|
Partial Approval |
IVRS - Inspection :*/ 1) BACK TO THE LAST LIST. PRV INSTALLED, EXPANSION TANK INSTALLED 2) WATER LINE SMALL LEAK AT PRV-PVC NIPPLE 3) NO SLEEVING 1 1/4" CU. WATER PASSES THRU 3" SLAB AT REAR OF HOUSE |
| 05/04/2004 |
BUILDING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :*/ 1) AT LAST INSPECTION NOTED STUCCO LATH WASN'T SIGNED OFF? NEED A LETTER FROM LATHING/CONTRACTOR STATING ALL WORK AWA DONE TO SPECS. 2) WATER SERVICE LINE WASN'T INSPECTED, NEED A PRESSURE TEST IF OVER 80 PSI. YOU WILL NEED A PRV INSTALLED, IF NO INTERNAL BY PASS IS BUILT INTO THE VALVE, EXPANSION TANK REQUIRED |
| 04/29/2004 |
BUILDING - FINAL |
|
Partial Approval |
IVRS - Inspection :*/ 1) WILL NEED TO ADDRESS ALL ITEMS FROM INSPECTION DATED 7/28/03 AND 7/24/03 2) NEED CERTIFICATIONS 3) STUCCO LATH WASN'T SIGNED OFF ? 4) YARD WATER LINE WASN'T SIGNED OFF 5) CONCRETE INSULATION AND STUCCO CARD |
| 07/28/2003 |
BUILDING - FINAL |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) NEED TO HAVE APPROVAL FOR SLOPE, RIP RAD SOIL CONDITION, BY ELIZ. EDER BACK FLOOD PLAIN 2) PLEASE HAVE POST TENSION INSPECTOR LOCK AT GARAGE END OF SLAB AT CABLES (TWO) CONCRETE SURFACE IS CRACKED |
| 07/25/2003 |
BUILDING - FINAL |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) NEED TO CHECK ON SLOPE OF RIP RAP, PER CC & R5 IS RETAINING WALL REQUIRED 2) NEED A CONCLUSION PAGE COMPLETE WITH, CONCRETE CYLINDER TEST RESULTS AND GABLE TENSIONING |
| 07/24/2003 |
BUILDING - FINAL |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) MOVE A/C FOR PROPER CLEARANCES 2) CONNECT GAS FLUE 3) CONNECT CONDENSATE 4) COLOR CODE WIRE FOR A/C CIRCUIT 5) OPEN NEUTRAL OUTLET IN GREAT ROOM 6) I WILL CHECK ON SET BACK TO GRADE AT PERIMETER OF EXTERIOR NAILS 7) NEED ALL CERTIFICATIONS, INSULATION, STUCCO AND CONCRETE |