Permit Details

Status:
C of o
Type:
COMMERCIAL NEW
Address NEW:
1720 W IRVINGTON RD
Apply Date:
07/18/2002
Applicant:
N/A
Description:
NEW:STORE/GAS STATION
Contractors:
  • HAWORTH CORPORATION , THE

Permit Reviews

Permit Number - T02CM03418
Permit Status: C of o
Permit Description: NEW:STORE/GAS STATION
Start Date Submittal Complete Date Status  
01/03/2003 REVISION 01/03/2003 COMPLETED Review Details
07/18/2002 3RD PARTY REVIEW-COMMERCIAL 09/04/2002 COMPLETED Review Details
08/16/2002 SITE 09/04/2002 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T02CM03418
Permit Status: C of o
Permit Description: NEW:STORE/GAS STATION
Total Outstanding Activity Conditions - 1
Date Name
07/18/2002 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T02CM03418
Permit Description: NEW:STORE/GAS STATION
Total Completed Inspections - 39
Date Description Inspector Results Comments
10/02/2002 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection 0000*
10/07/2002 ELECTRIC - UFER JORTA Approved IVRS - Inspection 0235*NOT APPROVED WILL NEED LETTER AND ALTERNATE METHOD BY ENGINEER. DISTRIBUTION CENTER CONDUITS TO 15FT BEYOND FRONT STORE WALL APRPOVED.
10/30/2002 FRAMING LHANLY Approved
10/30/2002 EXT METAL CLIPS/EXT SHEATHING LHANLY Approved IVRS - Inspection 0000*
11/04/2002 PLUMBING - ABOVE CEILING RMYERS Approved IVRS - Inspection 0000*
11/04/2002 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection 0000*1.) ABS DWV THUR ROOF 2.) COPPER PRESSURE TEST OK 3.) OK TO COVER WALLS AND CEILING.
11/04/2002 ELECTRIC - INTERMEDIATE MCAPISTR Approved IVRS - Inspection 0000*1.) INTERIOR PARTITIONS ROUGH IN IS OK. CHECK YOUR LAYOUT.
11/20/2002 SHEET ROCK NAILING LHANLY Approved IVRS - Inspection 0000*
12/12/2002 ELECTRIC - ABOVE CEILING JORTA Approved IVRS - Inspection 0000*
12/12/2002 ELECTRIC - UNDERGROUND JORTA Approved IVRS - Inspection 0000*
12/13/2002 MECHANICAL - ABOVE CEILING CWILLIAM Approved IVRS - Inspection 0000*INSULATE LINEAR DIFF. BOXES AS PER ITEM #6. MECH. NOTES ON SHT. M2.
12/13/2002 ROOF NAILING LHANLY Approved IVRS - Inspection 0000*
12/13/2002 BUILDING PRE-SLAB LHANLY Approved IVRS - Inspection 0000*
12/13/2002 EXCAVATION/LAYOUT REBAR & ZON LHANLY Approved IVRS - Inspection 0000*
12/24/2002 PLUMBING - SEWER HCS CONNECT RMYERS Approved 4" SDR 35 SEWER, FROM RETAINING WALL TO TIE-IN AT MANHOLE OK SEWER CROSSES WATER MAIN 24" BELOW. OK TO BACKFILL.
12/27/2002 MECHANICAL - TEMP PWR FOR TEST LHANLY Approved PER CHUCK WILLIAMS
12/27/2002 PLUMBING - TEMP POWER FOR TEST RMYERS Approved
12/27/2002 ELECTRIC - TEMP POWER FOR TEST JORTA Approved
12/27/2002 ELECTRIC - CABLE DROP JORTA Approved IVRS - Inspection 0000*PLEASE CALL INSPECTION CENTER FOR ALL TRADES TO SIGN OFF FOR TEMP POWER.
12/27/2002 BUILDING - TEMP POWER FOR TEST LHANLY Approved
12/30/2002 PLUMBING - FINAL RMYERS Approved IVRS - Inspection 0000*1.) CORRECTION MADE OK
2.) OK FOR C OF O PENDING ANY OTHER INSPECTION.
12/30/2002 PLUMBING - FINAL RMYERS Approved IVRS - Inspection 0999*
12/30/2002 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection 0000*
12/31/2002 SIGN - FINAL JSONKIN Approved IVRS - Inspection 0000*
12/31/2002 LANDSCAPE - FINAL PGILBERT Approved OK FOR TEMP C OF O.

COMPLETE LANDSCAPING PER PLAN.
12/31/2002 ENGINEERING - FINAL IVR USER Approved IVRS - Ri canceled
12/31/2002 MECHANICAL - FINAL CWILLIAM Approved FRAME COMB. ROOF TOP UNIT UNIT AS FUSED, NOT CORRECT.
2.) COND PVC PIPING
NEEDS TO BE PAINTED WHERE
EXPOSED
3.) WALL IN BOX A/H NEED TAGGLE SWITCH AT EACH UNIT.
12/31/2002 BUILDING - FINAL LHANLY Approved IVRS - Inspection 0000*/ 1.) OK TCO FOR STOCKING 2) FINISH BASE MOLDING IN BATHROOMS 2) FINISH SEALING EXTERIOR PENETRATIONS 3) PROVIDE APPROVED FINAL INSPECTIONS FROM FIRE, MECH, PLUMBING AND ELECTRIC INSPECTIONS 4) OK TCO
12/31/2002 BUILDING ABOVE CEILING LHANLY Approved IVRS - Inspection 0000*
01/06/2003 FIRE - FINAL LTHOMAS Approved
01/22/2003 MECHANICAL - INTERMEDIATE CWILLIAM Approved
01/22/2003 PLUMBING - GAS PRESSURE TEST RMYERS Approved
01/22/2003 ELECTRIC - FINAL RMAJUTA Approved
01/22/2003 U VALUE FOR WINDOW AMATHIES Approved
01/22/2003 STUCCO MESH AMATHIES Approved
01/22/2003 REINFORCED MASONRY PRE-GROUT AMATHIES Approved
01/22/2003 STEM WALL/RETAINING WALL AMATHIES Approved
11/10/2003 RIGHT OF WAY - FINAL THARVISO Approved
11/10/2003 PERMIT FINALED THARVES Approved