Permit: T02CM03418
Permit Details
Apply Date:
07/18/2002
Applicant:
N/A
Description:
NEW:STORE/GAS STATION
Contractors:
- HAWORTH CORPORATION , THE
Permit Reviews
Permit Number - T02CM03418
Permit Status: C of o
Permit Description: NEW:STORE/GAS STATION
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/03/2003 | REVISION | 01/03/2003 | COMPLETED |
| 07/18/2002 | 3RD PARTY REVIEW-COMMERCIAL | 09/04/2002 | COMPLETED |
| 08/16/2002 | SITE | 09/04/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM03418
Permit Status: C of o
Permit Description: NEW:STORE/GAS STATION
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 07/18/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T02CM03418
Permit Description: NEW:STORE/GAS STATION
Total Completed Inspections - 39
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/02/2002 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection 0000* |
| 10/07/2002 | ELECTRIC - UFER | JORTA | Approved | IVRS - Inspection 0235*NOT APPROVED WILL NEED LETTER AND ALTERNATE METHOD BY ENGINEER. DISTRIBUTION CENTER CONDUITS TO 15FT BEYOND FRONT STORE WALL APRPOVED. |
| 10/30/2002 | FRAMING | LHANLY | Approved | |
| 10/30/2002 | EXT METAL CLIPS/EXT SHEATHING | LHANLY | Approved | IVRS - Inspection 0000* |
| 11/04/2002 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection 0000* |
| 11/04/2002 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection 0000*1.) ABS DWV THUR ROOF 2.) COPPER PRESSURE TEST OK 3.) OK TO COVER WALLS AND CEILING. |
| 11/04/2002 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection 0000*1.) INTERIOR PARTITIONS ROUGH IN IS OK. CHECK YOUR LAYOUT. |
| 11/20/2002 | SHEET ROCK NAILING | LHANLY | Approved | IVRS - Inspection 0000* |
| 12/12/2002 | ELECTRIC - ABOVE CEILING | JORTA | Approved | IVRS - Inspection 0000* |
| 12/12/2002 | ELECTRIC - UNDERGROUND | JORTA | Approved | IVRS - Inspection 0000* |
| 12/13/2002 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | IVRS - Inspection 0000*INSULATE LINEAR DIFF. BOXES AS PER ITEM #6. MECH. NOTES ON SHT. M2. |
| 12/13/2002 | ROOF NAILING | LHANLY | Approved | IVRS - Inspection 0000* |
| 12/13/2002 | BUILDING PRE-SLAB | LHANLY | Approved | IVRS - Inspection 0000* |
| 12/13/2002 | EXCAVATION/LAYOUT REBAR & ZON | LHANLY | Approved | IVRS - Inspection 0000* |
| 12/24/2002 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | 4" SDR 35 SEWER, FROM RETAINING WALL TO TIE-IN AT MANHOLE OK SEWER CROSSES WATER MAIN 24" BELOW. OK TO BACKFILL. |
| 12/27/2002 | MECHANICAL - TEMP PWR FOR TEST | LHANLY | Approved | PER CHUCK WILLIAMS |
| 12/27/2002 | PLUMBING - TEMP POWER FOR TEST | RMYERS | Approved | |
| 12/27/2002 | ELECTRIC - TEMP POWER FOR TEST | JORTA | Approved | |
| 12/27/2002 | ELECTRIC - CABLE DROP | JORTA | Approved | IVRS - Inspection 0000*PLEASE CALL INSPECTION CENTER FOR ALL TRADES TO SIGN OFF FOR TEMP POWER. |
| 12/27/2002 | BUILDING - TEMP POWER FOR TEST | LHANLY | Approved | |
| 12/30/2002 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection 0000*1.) CORRECTION MADE OK 2.) OK FOR C OF O PENDING ANY OTHER INSPECTION. |
| 12/30/2002 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection 0999* |
| 12/30/2002 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection 0000* |
| 12/31/2002 | SIGN - FINAL | JSONKIN | Approved | IVRS - Inspection 0000* |
| 12/31/2002 | LANDSCAPE - FINAL | PGILBERT | Approved | OK FOR TEMP C OF O. COMPLETE LANDSCAPING PER PLAN. |
| 12/31/2002 | ENGINEERING - FINAL | IVR USER | Approved | IVRS - Ri canceled |
| 12/31/2002 | MECHANICAL - FINAL | CWILLIAM | Approved | FRAME COMB. ROOF TOP UNIT UNIT AS FUSED, NOT CORRECT. 2.) COND PVC PIPING NEEDS TO BE PAINTED WHERE EXPOSED 3.) WALL IN BOX A/H NEED TAGGLE SWITCH AT EACH UNIT. |
| 12/31/2002 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection 0000*/ 1.) OK TCO FOR STOCKING 2) FINISH BASE MOLDING IN BATHROOMS 2) FINISH SEALING EXTERIOR PENETRATIONS 3) PROVIDE APPROVED FINAL INSPECTIONS FROM FIRE, MECH, PLUMBING AND ELECTRIC INSPECTIONS 4) OK TCO |
| 12/31/2002 | BUILDING ABOVE CEILING | LHANLY | Approved | IVRS - Inspection 0000* |
| 01/06/2003 | FIRE - FINAL | LTHOMAS | Approved | |
| 01/22/2003 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | |
| 01/22/2003 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | |
| 01/22/2003 | ELECTRIC - FINAL | RMAJUTA | Approved | |
| 01/22/2003 | U VALUE FOR WINDOW | AMATHIES | Approved | |
| 01/22/2003 | STUCCO MESH | AMATHIES | Approved | |
| 01/22/2003 | REINFORCED MASONRY PRE-GROUT | AMATHIES | Approved | |
| 01/22/2003 | STEM WALL/RETAINING WALL | AMATHIES | Approved | |
| 11/10/2003 | RIGHT OF WAY - FINAL | THARVISO | Approved | |
| 11/10/2003 | PERMIT FINALED | THARVES | Approved |