Permit: T02CM03095
Permit Details
Apply Date:
06/26/2002
Applicant:
JESUS CARILLO
Description:
NEW:DUPLEX
Permit Reviews
Permit Number - T02CM03095
Permit Status: Final
Permit Description: NEW:DUPLEX
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/26/2002 | RESIDENTIAL BLDG/ZONING/FLOOD/WWM | 08/16/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM03095
Permit Status: Final
Permit Description: NEW:DUPLEX
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/26/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T02CM03095
Permit Description: NEW:DUPLEX
Total Completed Inspections - 24
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/21/2002 | ELECTRIC - UFER | JORTA | Approved | IVRS - Inspection 0000* |
| 08/26/2002 | EXCAVATION/LAYOUT REBAR & ZON | LHANLY | Approved | IVRS - Inspection 0000* |
| 09/30/2002 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection 0000*1.) ADDRESS POSTED. 2.) ABS DWV UNDERGROUND FOR BOTH UNITS TO BRANCH AT SOUTH UNIT OK WATER TEST ONE RISER TO TEN FEET. 3.) OK TO BACKFILL. |
| 09/30/2002 | STEM WALL/RETAINING WALL | LHANLY | Approved | IVRS - Inspection 0000* |
| 11/01/2002 | REINFORCED MASONRY PRE-GROUT | LHANLY | Approved | IVRS - Inspection 0000* |
| 11/19/2002 | ROOF NAILING | LHANLY | Approved | IVRS - Inspection 0000*DECK NAILING OK OK TO COVER. |
| 04/15/2003 | ELECTRIC - TEMPORARY SERVICE | DSANTACR | Approved | IVRS - Inspection 0000*1.) NEUTRAL CONDUCTOR NOT INDENTIFIED TO SUB PANEL. 2.) INSTALL PERMANENT ADDRESS LABEL ON EACH METER, MUST BE SCREWED OR RIVITED. WILL CHECK NEXT INSPECTION. OK TO CLEAR METER #2, ONLY TEMP SERVICE, OK CABLE DROP. |
| 05/08/2003 | PLUMBING - SEWER HCS CONNECT | TRINIVJR | Approved | IVRS - Inspection 0000*1.) SOIL WATER TEST FOR BLDG. SEWER IS OK 2.) OK TO BACKFILL TRENCH. 3.) MUST PROVIDE MIN. OF 50LBS OF AIR TEST OR METER PRESSURE. 4.) MUST INSTALL ISOLATIONS ON ALL WATER DISTRIBUTION THAT PENETRATES METAL STUDS. 5.) MUST STRAP DOWN OVERHEAD COPPER EVERY 6'. 6.) INSTALL CLOSET RINGS. |
| 05/08/2003 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | IVRS - Inspection 0999* |
| 06/24/2003 | ELECTRIC - UNDERGROUND | DSANTACR | Approved | IVRS - Inspection 0000*/ 1) NOTE THAT SERVICE ALREADY CLEARED. VERIFIED WITH CITY-OK CALL TEP REP. IF THERE IS A PROBLEM. NEED TO VERIFY LICENSED |
| 06/26/2003 | PLUMBING - GAS PRESSURE TEST | TRINIVJR | Approved | IVRS - Inspection 0000* |
| 06/26/2003 | PLUMBING - YARD WTR LINE/TEST | TRINIVJR | Approved | IVRS - Inspection 0000*/ 1) GAS PRESSURE TEST IS OK 2) YARD WATER LINE FROM METER TO BLDG SERVICE IS OK 3) OK TO BACKFILL TRENCH |
| 07/14/2003 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 10/24/2003 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection 0000* UNIT#1 OK FOR FRAME & DRYWALL CALL FOR INSP ON #2 |
| 11/17/2003 | ELECTRIC - CONSTRUCTION POWER | DSANTACR | Approved | IVRS - Inspection 0245*/ 1) ROMEX CONNECTOR MISSING IN 3/0 BOX IN FURNACE ROOM. 2) REPLACE OR COVER UNUSED OPENING ON 3 GANG SWITCH BOX IN LIVING ROOM. 3) PUSH IN BUSHING NOT APPROVED FOR ROMEX TERMINATION, MUST BE CLAMP TYPE. 4) DUPLEX REQUIRES LICENSED CONT. LEAVE NAME AND PHONE NUMBER OF LICENSED CONT. DOING WORK FOR VERIFICATION. |
| 11/17/2003 | FRAMING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 11/28/2003 | ELECTRIC - INTERMEDIATE | RMAJUTA | Approved | #2 OK TO COVER ELECTRICAL, FINAL APPROVAL WILL BE SUBJECT TO REGISTRAR OF CONTRACTORS VERIFICATION. |
| 03/08/2004 | PLUMBING - GAS PRESS TEST FNL | TRINIVJR | Approved | IVRS - Inspection 0000*/ GAS PRESSURE TEST IS OK. |
| 04/07/2004 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection 0000* |
| 04/07/2004 | ELECTRIC - CABLE DROP | DSANTACR | Approved | |
| 04/19/2004 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 04/22/2004 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :*/ CORRECTIONS MADE OK. PLBG FINAL OK. OK FOR C OF O PENDING ANY OTHER INSP. |
| 04/24/2004 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection :* |
| 04/26/2004 | PERMIT FINALED | AMATHIES | Approved |