Permit: T02CM03095

Parcel: 118122610


Addresses:

150 E 25TH ST #01

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
09/30/2002 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*1.) ADDRESS POSTED. 2.) ABS DWV UNDERGROUND FOR BOTH UNITS TO BRANCH AT SOUTH UNIT OK WATER TEST ONE RISER TO TEN FEET. 3.) OK TO BACKFILL.
09/24/2002 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*1.) IF YOU WISH TO CONTINUE RECEIVING INSPECTIONS PLEASE POST YOUR ADDRESS. 2.) A TRAP ARM MUST BE AT LEAST TWO PIPE DIAMETERS IN LENGTH FROM THE WEIR OF THE TRAP TO THE POINT OF VENT. 3.) ABS BLDG. SEWER MUST HAVE A MINIMUM OF TWELVE INCHES OF COVER 4.) MISSING DIRECTIONAL CLEAN OUT IN BETWEEN UNITS AS SHOWN ON PLAN 5.) PLEASE EXP