Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 09/30/2002 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection 0000*1.) ADDRESS POSTED. 2.) ABS DWV UNDERGROUND FOR BOTH UNITS TO BRANCH AT SOUTH UNIT OK WATER TEST ONE RISER TO TEN FEET. 3.) OK TO BACKFILL. |
| 09/24/2002 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*1.) IF YOU WISH TO CONTINUE RECEIVING INSPECTIONS PLEASE POST YOUR ADDRESS. 2.) A TRAP ARM MUST BE AT LEAST TWO PIPE DIAMETERS IN LENGTH FROM THE WEIR OF THE TRAP TO THE POINT OF VENT. 3.) ABS BLDG. SEWER MUST HAVE A MINIMUM OF TWELVE INCHES OF COVER 4.) MISSING DIRECTIONAL CLEAN OUT IN BETWEEN UNITS AS SHOWN ON PLAN 5.) PLEASE EXP |