Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 04/22/2004 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection :*/ CORRECTIONS MADE OK. PLBG FINAL OK. OK FOR C OF O PENDING ANY OTHER INSP. |
| 04/19/2004 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) MUST PROVIDE HOSE BIB VACUUM BREAKER AT ALL HOSE BIBS. 2) MUST PROVIDE 2 - 10X10 LOUVER GRILLS LOCATED 12" BELOW CEILING AND 12" ABOVE FLOOR FOR WTR HTRS. 3) MUST EXTEND T&P DRAIN AND TERMINATE 6" ABOVE SLAB. 4) MUST EXPOSE C.O. FOR KITCHEN SINKS. |
| 04/07/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) PROVIDE INSP. HISTORY FOR INTERMEDIATE APPROVAL. 2) ABS MAY NOT BE INSTALLED IN AN EXPOSED EXTERIOR LOCATION. 3) ALL PENETRATIONS REQUIRE FLASHINGS. |