Permit: T02CM02637
Permit Details
Apply Date:
05/29/2002
Applicant:
TAVRICO INC ,
Description:
ADDITION:3 BEDROOMS & 2 BATHS & NEW UNIT TO MAKE DUPLEX
Contractors:
- TAVRICO INC ,
Permit Reviews
Permit Number - T02CM02637
Permit Status: C of o
Permit Description: ADDITION:3 BEDROOMS & 2 BATHS & NEW UNIT TO MAKE DUPLEX
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
05/29/2002 | RESIDENTIAL BLDG/ZONING/FLOOD/WWM | 07/08/2002 | COMPLETED |
07/25/2002 | REVISION | 07/25/2002 | COMPLETED |
07/30/2002 | REVISION | 07/31/2002 | COMPLETED |
10/07/2002 | REVISION | 10/08/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM02637
Permit Status: C of o
Permit Description: ADDITION:3 BEDROOMS & 2 BATHS & NEW UNIT TO MAKE DUPLEX
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
05/29/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T02CM02637
Permit Description: ADDITION:3 BEDROOMS & 2 BATHS & NEW UNIT TO MAKE DUPLEX
Total Completed Inspections - 20
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/29/2002 | PLUMBING - ROUGH, SOIL | JSTANLEY | Approved | IVRS - Inspection 0000* REVISED PLAN ON JOB APPROVED BY OUR OFFICE 7-25-02. TEST OK ON UNDERGROUND SOIL ONLY OK TO BACK FILL. ANY WATER UNDER SLAB AT TOP OUT. CALL FOR WILL REQUIRE TEST. |
08/01/2002 | BUILDING PRE-SLAB | AMATHIES | Approved | IVRS - Inspection 0000* |
08/01/2002 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | |
08/09/2002 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
08/09/2002 | EXT METAL CLIPS/EXT SHEATHING | AMATHIES | Approved | IVRS - Inspection 0000* |
08/20/2002 | PLUMBING - SEWER HCS CONNECT | JSTANLEY | Approved | |
08/27/2002 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection 0000*OK FOR SHEET ROCK. |
08/27/2002 | PLUMBING - INTERMEDIATE | JSTANLEY | Approved | IVRS - Inspection 0000*COMPLETE FHA STRAPS & MID STORY ANCHOR WILL SEE COSET COLLER AT LATER DATE. |
08/27/2002 | U VALUE FOR WINDOW | AMATHIES | Approved | IVRS - Inspection 0000* |
08/27/2002 | STUCCO MESH | AMATHIES | Approved | IVRS - Inspection 0000* |
08/27/2002 | FRAMING | AMATHIES | Approved | IVRS - Inspection 0000*NOTE ON TENNANT SEPERATION WALL: REMOVE NAILERS TO ALLOW SHEETROCK TO RUN UP TO UNDERSIDE OF ROOF DECK |
09/03/2002 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
10/02/2002 | ELECTRIC - TEMPORARY SERVICE | RHOLLAND | Approved | IVRS - Inspection 0000*SENT TEP ON 10/3/02 AT 9:15AM. |
10/14/2002 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | |
10/14/2002 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection 0000* |
10/15/2002 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection 0000*1.) USE AN APPROVED FITTING AT L.B. ALSO CANNOT INSTALL ROMEX IN A COMPLETE RACEWAY SYSTEM. 2.) CORRECTLY IDENTIFY ON GROUNDED CONDUCTORS CK ON FINAL FOR 1422 E LEE. CLOSET FIXTURES NOT INSTALLED AT THIS TIME. |
10/16/2002 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000*OK FOR C OF O. |
10/16/2002 | PLUMBING - FINAL | RMYERS | Approved | 1.) PLUMBING YARDWATER OK PRESSURE TEST OK OK TO COVER 2.) PLUMBING FINAL OK 3.) OK FOR C OF O PENDING ANY OTHER INSPECTION. |
10/17/2002 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection 0000* |
10/18/2002 | PERMIT FINALED | AMATHIES | Approved |