Permit: T02CM02411
Permit Details
Status:
C of o
Type:
COMMERCIAL NEW
Address:
4727 E CAMP LOWELL DR
Address NEW:
4727 E CAMP LOWELL DR
Apply Date:
05/14/2002
Applicant:
METRO PERMIT EXPRESS, INC
Description:
NEW:MEDICAL OFFICE
Architects:
- EGLIN, EVAN SAR
Contractors:
- VENTURE WEST INC
Permit Reviews
Permit Number - T02CM02411
Permit Status: C of o
Permit Description: NEW:MEDICAL OFFICE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/14/2003 | REVISION | 03/05/2003 | COMPLETED |
| 02/28/2003 | REVISION | 03/05/2003 | COMPLETED |
| 03/21/2003 | REVISION | 04/25/2003 | COMPLETED |
| 05/14/2002 | 3RD PARTY REVIEW-COMMERCIAL | 07/19/2002 | COMPLETED |
| 05/28/2003 | 3RD PARTY REVIEW-REVISION/OTHER | 05/30/2003 | COMPLETED |
| 06/02/2003 | 3RD PARTY REVIEW-REVISION/OTHER | 06/06/2003 | COMPLETED |
| 07/19/2002 | RESUBMITTAL | 07/19/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM02411
Permit Status: C of o
Permit Description: NEW:MEDICAL OFFICE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/14/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T02CM02411
Permit Description: NEW:MEDICAL OFFICE
Total Completed Inspections - 38
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/08/2002 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | 1.) SOIL WATER TEST IS OK 2.) BLDG. DRAIN IS STUBBED OUT @ TWO WAY C.O. ONLY. 3.) OK TO BACKFILL TRENCH. 4.) NOTE: WILL REQUIRE A REVISED & APPROVED DRAWING ON WASTE & VENT SYSTEM AS REQUESTED. |
| 10/17/2002 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection 0000*NOTES OK U.G. CONDUIT FOR PANEL FEEDERS, COMM. ONLY. |
| 10/22/2002 | ELECTRIC - UFER | JORTA | Approved | IVRS - Inspection 0000*NO UFER INSTALLED PLEASE HAVE UNDERGROUND ADDED TO PERMIT. 1.) ALL PATIENT CARE AREAS TO BE AS PER 517 PVC NOT ALLOWED. |
| 10/22/2002 | BUILDING PRE-SLAB | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 10/22/2002 | STEM WALL/RETAINING WALL | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 10/22/2002 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 10/29/2002 | REINFORCED MASONRY PRE-GROUT | AQUIROZ | Approved | IVRS - Inspection 0000*1ST LIFT OK. |
| 12/18/2002 | EXT METAL CLIPS/EXT SHEATHING | AQUIROZ | Approved | IVRS - Inspection 0000*ON EXTERIOR SHEATHIN. |
| 02/05/2003 | ROOF NAILING | RSUBA | Approved | IVRS - Inspection 0000* |
| 02/20/2003 | PLUMBING - SEWER HCS CONNECT | JSTANLEY | Approved | IVRS - Inspection 0000* |
| 03/07/2003 | PLUMBING - INTERMEDIATE | JSTANLEY | Approved | IVRS - Inspection 0000* |
| 03/10/2003 | FRAMING | RSUBA | Approved | IVRS - Inspection 0000* |
| 03/27/2003 | STUCCO MESH | AMATHIES | Approved | IVRS - Inspection 0000* |
| 04/29/2003 | PLUMBING - ABOVE CEILING | JSTANLEY | Approved | IVRS - Inspection 0000* |
| 04/30/2003 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | IVRS - Inspection 0000*OK TO COVER GRID. |
| 05/09/2003 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection 0000* |
| 05/09/2003 | SHEET ROCK NAILING | HLEYVA | Approved | IVRS - Inspection 0000* |
| 05/09/2003 | U VALUE FOR WINDOW | HLEYVA | Approved | IVRS - Inspection 0000* |
| 05/09/2003 | BUILDING ABOVE CEILING | HLEYVA | Approved | IVRS - Inspection 0000* |
| 05/15/2003 | ELECTRIC - ABOVE CEILING | RHOLLAND | Approved | IVRS - Inspection 0000*WHAT IS THE REFERENCE OF THE LABEL THAT STATES "LNG LANDING SUITABLE FOR (3) LUGS PER PASS & NEUTRAL" WE HAVE 4 LUGS AT EACH PHASE AND 5 LUGS AT THE NEUTRAL 2.) PLEASE PROVIDE A LETTER ON COMPANY LETTER HEAD FOR TORQUE VALVES OF SERVICE EQUIPMENT. 3.) REJECTION PINS ARE NEEDED. 4.) PLEASE PROVIDE APPROVED PLANS ON SITE. |
| 05/19/2003 | ELECTRIC - CONSTRUCTION POWER | RHOLLAND | Approved | IVRS - Inspection 0000*OK TEMP POWER FOR TEST. |
| 05/28/2003 | RIGHT OF WAY - FINAL | PWHIDDON | Approved | |
| 05/28/2003 | NPPO - FINAL | PGILBERT | Approved | |
| 05/28/2003 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection 0000* |
| 05/28/2003 | LANDSCAPE - FINAL | PGILBERT | Approved | |
| 05/29/2003 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection 0000*/ 1) OK FINAL SUBJECT TO OTHER INSPECTORS |
| 05/29/2003 | ELECTRIC - CABLE DROP | RHOLLAND | Approved | |
| 05/30/2003 | FIRE - FINAL | JEGAN | Approved | IVRS - Inspection 0000* |
| 05/30/2003 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
| 05/30/2003 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | |
| 05/30/2003 | FIRE SPKLR - UG PIPING FLUSH | LTHOMAS | Approved | |
| 05/30/2003 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | |
| 06/09/2003 | ENGINEERING - FINAL | DROBERTS | Approved | |
| 06/10/2003 | PLUMBING - FINAL | JSTANLEY | Approved | IVRS - Inspection 0000* PLEASE NOT REVISED PLAN ON JOB SITE WATER FOR ABOVE ADDRESS |
| 06/10/2003 | PLUMBING - YARD WTR LINE/TEST | JSTANLEY | Approved | |
| 06/12/2003 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 06/25/2003 | PERMIT FINALED | RSUBA | Approved | |
| 06/25/2003 | BUILDING - FINAL | RSUBA | Approved |