Permit: T02CM02389
Permit Details
Apply Date:
05/13/2002
Applicant:
FRANCISCO FIMBRES
Description:
NEW:DUPLEX
Contractors:
- TUCSON CUSTOM BUILDERS L C ,
Permit Reviews
Permit Number - T02CM02389
Permit Status: Final
Permit Description: NEW:DUPLEX
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/04/2003 | REVISION | 03/04/2003 | COMPLETED |
| 05/13/2002 | RESIDENTIAL BLDG/ZONING/FLOOD/WWM | 05/28/2002 | COMPLETED |
| 11/18/2002 | REVISION | 11/18/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM02389
Permit Status: Final
Permit Description: NEW:DUPLEX
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/13/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T02CM02389
Permit Description: NEW:DUPLEX
Total Completed Inspections - 25
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/05/2002 | ELECTRIC - UFER | JORTA | Approved | IVRS - Inspection 0000* |
| 06/05/2002 | EXCAVATION/LAYOUT REBAR & ZON | RSUBA | Approved | IVRS - Inspection 0000* |
| 06/11/2002 | STEM WALL/RETAINING WALL | AMATHIES | Approved | IVRS - Inspection 0000* |
| 11/20/2002 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection 0000*1.) OK PER REVISED APPROVED PLAN 2.) OK TO BACKFILL. |
| 12/11/2002 | BUILDING PRE-SLAB | LHANLY | Approved | IVRS - Inspection 0000* |
| 03/19/2003 | REINFORCED MASONRY PRE-GROUT | AMATHIES | Approved | IVRS - Inspection 0000* |
| 04/01/2003 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 05/20/2003 | FRAMING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 05/23/2003 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection 0000*/ 1) LEAVE NAME AND PHONE OF LICENSED ELECTRICAL CONTR. DOING WORK |
| 05/27/2003 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | |
| 05/29/2003 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | IVRS - Inspection 0000* |
| 05/29/2003 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection 0000*/ 1) WILL REQUIRE A LETTER FROM THE ARCHETECT ALLOWING PEX IN LIEU OF COPPER WATER PIPING 2) INVATORY TRAP ARM EXCEEDS 90 DEGREE CHANGE OF DIRECTION. WILL REQUIRE ADDITIONAL CLEAN-OUT ON TRAP ARM, INSTALLED IN AN APPROVED MANNER AS NOTED ON PLAN PAGE 7 PLUMBING 3) OK TO COVER WALLS |
| 05/29/2003 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection 0999*/ 1) TRAP ARM FOR MASTER BATH LAVATORY CAN ONLY HAVE ONE 90 DEGREE 2) APPROVED PLAN SHOWS GAS LINES TO BE LOCATED AT PARTY WALL. CHECK WITH SOUTHWEST GAS ON LOCATION OF METERS FOR 3'-0" CLEARANCE FROM WINDOWS 3) GAS PRESSURE TEST IS OK 4) OVER HEAD WATER DISTRIBUTION AND TEST IS OK |
| 06/12/2003 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 07/01/2003 | ELECTRIC - CABLE DROP | DSANTACR | Approved | IVRS - Inspection 0000* |
| 07/01/2003 | ELECTRIC - UNDERGROUND | DSANTACR | Approved | IVRS - Inspection 0000* |
| 07/08/2003 | ELECTRIC - CONSTRUCTION POWER | DSANTACR | Approved | IVRS - Inspection 0000* |
| 07/08/2003 | ELECTRIC - TEMPORARY SERVICE | DSANTACR | Approved | IVRS - Inspection 0000* |
| 07/18/2003 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection 0000*/ 1) CORRECTIONS MADE-OK 2) WATER TEST-OK, TRANSITION FITTINGS OK 3) OK TO BACKFILL |
| 10/24/2003 | PLUMBING - YARD WTR LINE/TEST | RRICH | Approved | IVRS - Inspection 0000*/ 1) 1/2" PIPING CONNECTIONS TO 2-3/4" METERS ARE APPROVED. USING SCH 40 PVC PIPE AND FITTINGS |
| 11/05/2003 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 11/05/2003 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection 0000*/1) PLBG FINAL IS OK. 2) OK FOR C OF O. |
| 11/05/2003 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection 0000*/ 1) OK TO CLEAR ONE AND TWO 2) SENT TO TEP ON 11/06AM |
| 11/17/2003 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection 0000* |
| 11/18/2003 | PERMIT FINALED | AMATHIES | Approved |