Permit: T02CM02333
Permit Details
Status:
C of o
Type:
COMMERCIAL NEW
Address:
8801 E TANQUE VERDE RD
Address NEW:
8801 E TANQUE VERDE RD
Apply Date:
05/09/2002
Applicant:
SIERRA LAND SURVEYING AND DEVELO
Description:
MANAGERS UNIT:RESIDENCE
Contractors:
- SIERRA LAND SURVEYING AND DEVELO
Permit Reviews
Permit Number - T02CM02333
Permit Status: C of o
Permit Description: MANAGERS UNIT:RESIDENCE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/09/2002 | COMMERCIAL NEW | 05/30/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM02333
Permit Status: C of o
Permit Description: MANAGERS UNIT:RESIDENCE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/09/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T02CM02333
Permit Description: MANAGERS UNIT:RESIDENCE
Total Completed Inspections - 30
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/05/2002 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection 0000*SOIL WATER TEST IS OK 2. BLDG DRAIN IS STUBBED OUT @ TWO WAY C.O. ONLY 3.) OK TO BACKFILL TRENCH. |
| 08/07/2002 | ELECTRIC - UFER | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 08/07/2002 | BUILDING PRE-SLAB | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 08/30/2002 | PLUMBING - SEWER HCS CONNECT | TRINIVJR | Approved | IVRS - Inspection 0999*1.) MUST USE PROPER TRANSISION GLUE @ CONNECTION. WHERE SDR-35 AND ACH 40 CONNECT. 2.) PRIVATE SEWER REQUIRE A FLEXIBLE COMPRESSION JOINT NO CLOSER THAN 12" AND NO THAN 3FT FROM THE MANHOLE SEE SECTION 719.6 94 UPC 3.) RE TEST SYSTEM. |
| 09/09/2002 | STUCCO MESH | RSUBA | Approved | IVRS - Inspection 0000* |
| 12/20/2002 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection 0000*INSULATE SIDEWALL BOXES & TWYES OK FOR SHEET ROCK. |
| 12/20/2002 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection 0000* |
| 12/20/2002 | ELECTRIC - ABOVE CEILING | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 12/20/2002 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection 0000*EXCLUDES SERVICE EQUIPMENT. |
| 12/20/2002 | U VALUE FOR WINDOW | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 12/20/2002 | BUILDING ABOVE CEILING | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 12/20/2002 | FRAMING | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 12/20/2002 | ROOF NAILING | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 12/20/2002 | EXT METAL CLIPS/EXT SHEATHING | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 12/30/2002 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | IVRS - Inspection 0000*NOTIFIED CUSTOMER BY PHONE NO INSPECTION TODAY. 1.) SOIL WATER TEST IS OK 2.) OVERHEAD WATER DISTRIBUTION IS OK 3.) GAS PRESSURE TEST IS OK. |
| 02/18/2003 | SHEET ROCK NAILING | RSUBA | Approved | IVRS - Inspection 0000* |
| 07/28/2003 | PLUMBING - YARD WTR LINE/TEST | JSTANLEY | Approved | IVRS - Inspection 0000*/ 1) OK TO BACKFILL |
| 07/29/2003 | ELECTRIC - CABLE DROP | RHOLLAND | Approved | IVRS - Inspection 0000*SENT TO TEP ON 7/30AM |
| 08/13/2003 | PLUMBING - GAS PRESSURE TEST | JSTANLEY | Approved | IVRS - Inspection 0000* |
| 08/19/2003 | PLUMBING - FINAL | JSTANLEY | Approved | IVRS - Inspection 0000*/LAST INSPECTOR ON JOB PLEASE PROVIDE GAS CARD. |
| 08/19/2003 | ELECTRIC - FINAL | RMAJUTA | Approved | IVRS - Inspection 0000*SENT TO TEP 0820AM SUBJECT TO ALL OTHER INSPECTORS. ALL INSPECTORS HAV SIGNED OFF OK TO CLEAR ECO |
| 08/19/2003 | BUILDING - FINAL | RSUBA | Approved | IVRS - Inspection 0000* |
| 08/19/2003 | EXCAVATION/LAYOUT REBAR & ZON | RSUBA | Approved | |
| 08/20/2003 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 08/21/2003 | SIGN - FINAL | JSONKIN | Approved | IVRS - Inspection 0000* |
| 08/21/2003 | FIRE - FINAL | JEGAN | Approved | IVRS - Inspection 0000* |
| 09/02/2003 | RIGHT OF WAY - FINAL | PWHIDDON | Approved | |
| 09/02/2003 | LANDSCAPE - FINAL | PGILBERT | Approved | REVEG 30' NATURAL BUFFER AREA. CONTACT JOE LINVILLE 791-5550 EXT 1118 FOR REQUIREMENTS. |
| 11/26/2003 | PERMIT FINALED | DROBERTS | Approved | |
| 11/26/2003 | ENGINEERING - FINAL | DROBERTS | Approved |