Permit: T02CM02168
Permit Details
Apply Date:
04/29/2002
Applicant:
VINT, ROBERT WALTER
Description:
ADDITION:CLASSROOMS/RESTROOMS/OFFICE
Contractors:
- COBRE BUILDING SYSTEMS INC ,
Permit Reviews
Permit Number - T02CM02168
Permit Status: C of o
Permit Description: ADDITION:CLASSROOMS/RESTROOMS/OFFICE
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/29/2002 | 3RD PARTY REVIEW-COMMERCIAL | 05/20/2002 | COMPLETED |
07/18/2002 | REVISION | 07/18/2002 | COMPLETED |
09/05/2002 | REVISION | 11/25/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM02168
Permit Status: C of o
Permit Description: ADDITION:CLASSROOMS/RESTROOMS/OFFICE
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
04/29/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T02CM02168
Permit Description: ADDITION:CLASSROOMS/RESTROOMS/OFFICE
Total Completed Inspections - 35
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/01/2002 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | 1.) SOIL WATER TEST IS OK 2.) BLDG. DRAIN IS STUBBED OUT OF BLDG. ONLY. 3.) NOTE: WILL REQUIRE A REVISED & APPROVED DRAWING SHOWING P-10 FIXTURE WASTE LINE CONNECTING TO BLDG. DRAIN IN A-11 PRIOR TO FINAL INSPECTION. 4.) THIS INSPECTION RMS #A-1,A-5,A-3,A-8,A-10, A-11. AND EXSISTING RETRO FIT. 5.) OK TO BACKFILL TRENCH. |
09/03/2002 | BUILDING PRE-SLAB | AQUIROZ | Approved | IVRS - Inspection 0000* |
09/18/2002 | PLUMBING - SEWER HCS CONNECT | TRINIVJR | Approved | IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) MAN HOLE TAP IS OK 3.) NOTE: CONTRACTOR SAID HE WILL INSTALL A MECH. FLEXIBLE JOINT WITHIN 3'-0" OF MANHOLE PRIOR TO BACKFILL. |
10/21/2002 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved | IVRS - Inspection 0000* |
10/21/2002 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection 0000* |
10/22/2002 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection 0000*NEED TO SEE BOILER VENT. CHECKED ROOMS IN BLDG. A. OK FOR SHEET ROCK NEED TO SEE DRYER VENT. |
10/22/2002 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection 0000* |
10/22/2002 | BUILDING ABOVE CEILING | AQUIROZ | Approved | IVRS - Inspection 0000* |
10/22/2002 | FRAMING | AQUIROZ | Approved | IVRS - Inspection 0000* |
10/24/2002 | STUCCO MESH | AMATHIES | Approved | IVRS - Inspection 0000* |
11/01/2002 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection 0000* |
11/20/2002 | RIGHT OF WAY - FINAL | PWHIDDON | Approved | TEMP ONLY |
11/20/2002 | ENGINEERING - FINAL | LMAKUS | Approved | |
11/21/2002 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection 0000*PLBG FINAL IS OK 2.) OK FOR C OF O. |
11/21/2002 | PLUMBING - GAS PRESSURE TEST | TRINIVJR | Approved | |
11/21/2002 | PLUMBING - YARD WTR LINE/TEST | TRINIVJR | Approved | |
11/21/2002 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | |
11/21/2002 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection 0000*COMPLETE WIRING & CONNECTIONS FOR MAKE UP AIR UNIT SOUTH END. OK TEMP C OF O. |
11/22/2002 | FIRE - FINAL | JEGAN | Approved | IVRS - Inspection 0000* |
11/22/2002 | FIRE - ALARM FINAL | JEGAN | Approved | IVRS - Inspection 0000* |
11/22/2002 | FIRE SPKLR - FINAL | JEGAN | Approved | IVRS - Inspection 0000* |
11/22/2002 | PLUMBING - ABOVE CEILING | TRINIVJR | Approved | |
11/25/2002 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000*HAVE YOUR PLUMBING INSPECTOR CHECK WATER PIPING ON ROOF FOR BOILER. FINISH CONNECTING MAKE UP AIR UNIT & EXHAUST FAN. PROVIDE SCREWS IN WATER HEATER VENT & BOILER VENT. FINISH INSTALLING DRYER VENT. ARCHITECT SENT REVISION FOR MECHANICAL CHNAGES IN MAINTENANCE SHOP. OK FOR TEMP C OF O. |
11/25/2002 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | |
11/25/2002 | FIRE SPKLR - UG PIPING FLUSH | LTHOMAS | Approved | |
11/25/2002 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | |
11/25/2002 | ELECTRIC - UFER | RMAJUTA | Approved | IVRS - Inspection 0000* |
11/26/2002 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection 0000*TEMP C OF O. |
11/26/2002 | U VALUE FOR WINDOW | AQUIROZ | Approved | IVRS - Inspection 0000* |
11/26/2002 | ROOF NAILING | AQUIROZ | Approved | IVRS - Inspection 0000* |
11/26/2002 | REINFORCED MASONRY PRE-GROUT | AQUIROZ | Approved | IVRS - Inspection 0000* |
11/26/2002 | STEM WALL/RETAINING WALL | AQUIROZ | Approved | IVRS - Inspection 0000* |
11/26/2002 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | IVRS - Inspection 0000* |
11/27/2002 | SIGN - FINAL | CSTEPHEN | Approved | APPROVED FOR TEMPORARY C OF O. PER D.C. |
02/25/2003 | PERMIT FINALED | AQUIROZ | Approved |