Permit: T02CM01722
Permit Details
Apply Date:
04/04/2002
Applicant:
GREENWOOD INTERIORS ,
Description:
TI:RETAIL
Contractors:
- GREENWOOD INTERIORS ,
Permit Reviews
Permit Number - T02CM01722
Permit Status: C of o
Permit Description: TI:RETAIL
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/04/2002 | COMMERCIAL TI | 04/30/2002 | COMPLETED |
05/13/2002 | REVISION | 06/05/2002 | COMPLETED |
05/16/2002 | REVISION | 05/20/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T02CM01722
Permit Status: C of o
Permit Description: TI:RETAIL
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
04/04/2002 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T02CM01722
Permit Description: TI:RETAIL
Total Completed Inspections - 24
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/01/2002 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK. 2.) P.O.C. OF NEW BLDG DRAIN TO EXSISTING BLDG. DRAIN IS OK 3.) NOTE. WILL REQUIRE A REVISED AND APPROVED DRAWING ON WASTE & VENT SYSTEM AND P.O.C. OF NEW BLDG DRAIN TO EXSISTING BLDG. DRAIN PRIOR TO NEXT INSPECTION. |
05/22/2002 | SHEET ROCK NAILING | RSUBA | Approved | IVRS - Inspection 0000* |
06/05/2002 | PLUMBING - ABOVE CEILING | TRINIVJR | Approved | IVRS - Inspection 0000*1.) DUTCHMAN FOR CLOSET RING HAS BEEN INSTALLED OK FOR TRIM. |
06/07/2002 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection 0000*SECONDARY DRAIN PANS NOT CENTERED CORRECTLY UNDER AIR HANDLERS UNITS 1 & 3. 2.) SEAL HOLES IN SUPPLY DUCT WHERE SMOKE DETECTOR WERE REMOVED. 3.) LABEL AIR HANDLERS W/UNIT NUMBER. 4.) UNIT #1 NEEDS MORE INSULATION ON SUCTION LINE. 5.) MARK DATA PLATES ON AIR HANDLERS W/PROPER HEAT KIT INSTALLED. BE SURE OVER CURRENT PROTECTION CORRSPONDS W//DATA PLATE. WILL CHECK ON FINAL. OK FOR PARTIAL CEILING TILES |
06/07/2002 | ELECTRIC - ABOVE CEILING | RMAJUTA | Approved | IVRS - Inspection 0000* |
06/11/2002 | FIRE - FINAL | LTHOMAS | Approved | |
06/11/2002 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
06/11/2002 | FRAMING | RSUBA | Approved | IVRS - Inspection 0000* |
06/12/2002 | ELECTRIC - FINAL | MCAPISTR | Approved | IVRS - Inspection 0000* |
06/13/2002 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection 0000*1.) PLBG FINAL IS OK 2.) OK FOR C OF O. |
06/14/2002 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000*OK FOR C OF O. |
07/16/2002 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | |
07/16/2002 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | |
07/16/2002 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | |
07/16/2002 | BUILDING - FINAL | RSUBA | Approved | |
07/16/2002 | BUILDING ABOVE CEILING | RSUBA | Approved | |
07/16/2002 | ROOF NAILING | RSUBA | Approved | |
07/16/2002 | REINFORCED MASONRY PRE-GROUT | RSUBA | Approved | |
07/16/2002 | STEM WALL/RETAINING WALL | RSUBA | Approved | |
07/16/2002 | EXCAVATION/LAYOUT REBAR & ZON | RSUBA | Approved | |
07/17/2002 | RIGHT OF WAY - FINAL | PWHIDDON | Approved | |
07/17/2002 | ENGINEERING - FINAL | DROBERTS | Approved | |
07/19/2002 | SIGN - FINAL | JYBARRA | Approved | |
07/25/2002 | PERMIT FINALED | JYBARRA | Approved |