Permit: T01CM05969
Permit Details
Apply Date:
12/10/2001
Applicant:
N/A
Description:
NEW:APARTMENTS
Contractors:
- LECHNER CONSTRUCTION INC ,
Permit Reviews
Permit Number - T01CM05969
Permit Status: C of o
Permit Description: NEW:APARTMENTS
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/12/2003 | 3RD PARTY REVIEW-REVISION/OTHER | 07/07/2003 | COMPLETED |
| 10/08/2002 | RESUBMITTAL | 10/08/2002 | COMPLETED |
| 12/12/2001 | 3RD PARTY REVIEW-COMMERCIAL | 10/08/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T01CM05969
Permit Status: C of o
Permit Description: NEW:APARTMENTS
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/10/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T01CM05969
Permit Description: NEW:APARTMENTS
Total Completed Inspections - 37
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/19/2002 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection 0000* 1.) SOIL WATER TEST IS OK 2.) BLDG. DRAIN IS STUBBED OUT @ TWO WAY C.O. ONLY. 3.) OK TO BACKFILL TRENCH. |
| 02/03/2003 | ELECTRIC - UFER | RHOLLAND | Approved | IVRS - Inspection 0000*OK 2 - #4 TO REBAR. |
| 02/03/2003 | BUILDING PRE-SLAB | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 02/19/2003 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | |
| 05/05/2003 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 05/05/2003 | EXT METAL CLIPS/EXT SHEATHING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 07/08/2003 | PLUMBING - SEWER HCS CONNECT | JSTANLEY | Approved | IVRS - Inspection 0000* |
| 07/29/2003 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 08/07/2003 | ELECTRIC - ABOVE CEILING | RHOLLAND | Approved | IVRS - Inspection 0000* |
| 08/07/2003 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection 0000*/ 1) OK ROUGH ELECTRIC |
| 08/08/2003 | STUCCO MESH | AQUIROZ | Approved | |
| 08/25/2003 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 08/25/2003 | FRAMING | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 03/17/2004 | ELECTRIC - CABLE DROP | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 04/14/2004 | ELECTRIC - UNDERGROUND | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 04/19/2004 | ELECTRIC - TEMPORARY SERVICE | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 04/20/2004 | TEP CLEARANCE - AM | JKOZUCH | Approved | |
| 12/23/2005 | BUILDING - PROGRESS | SLONG | Approved | PAINT, TEXTURE, CARPETS, APPLIANCES, FIXTURES-PROGRESS OK |
| 11/22/2006 | MECHANICAL - FINAL | JWEATHER | Approved | DEAN LEFT A MESSAGE ON MY VOICE MAIL TO CANCEL INSPECTION FOR MECH FINAL SCHEDULED FOR 11/24/06. WENT AHEAD AND REMOVED IT FROM CALENDAR SO IT WOULD NOT PRINT OUT ON 11/24/06 |
| 11/28/2006 | ELECTRIC - FINAL | CCLEMENS | Approved | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. INSTALL FRESH BATTERIES IN SMOKE DETECTORS - NEC 110.3B 2. RANGE ANTI-TIP BRACKETS NOT PROPERLY INSTALLED - NEC 110.3B 3. FINISH EXTERIOR SITE LIGHTING 4. INSTALL BULBS CORRECT WATTAGE IN ALL FIXTURES 5. SHOWER TRIM REQUIRED IN SHOWER LIGHT - NEC 410.4 6. PROVIDE INSTALLATION INSTRCUTIONS FOR SMOKE DETECTORS IT APPEARS SOME MAY NOT BE CORRECTLY LOCATED (SAME MANUFACTURER OF SMOKES) -- 110.3B 7. SMOKE DETECTOR, LIGHTING AND RECEPTACLE WIRING IN BEDROOMS TO COMPLY WITH NEC 210.12B 8. PANEL DIRECTORY NOT CORRECTLY IDENTIFIED - NEC 408.4 9. TIGHTEN ANY LOOSE DEVICES AND REPLACE ANY CRACKED DEVICE COVERS. 10. TIGHTEN WATER HEATER GROUND INSPECTION FOR THE INTERIOR OF UNIT #13103 ONLY CHECK FOR THESE AND OTHER CORRECTIONS THROUGHOUT SERVICE DISCONNECTS DO NOT DISCONNECT ALL UNGROUNDED CONDUCTORS IN STRUCTURE. |
| 11/29/2006 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* CALL IN AND HAVE APPROVED ALL REQUIRED INSPECTIONS PRIOR TO CALLING INSPECTOR. |
| 12/18/2006 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :* 1. HAVE PLUMBER CHECK W & O ON TWO UNITS OK TO COVER 2. YARDWATER INSTALLED W/O INSPECTION CONTRACTOR POTHOLED PIPING CONNECTIONS LOOK OK |
| 12/18/2006 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection :* |
| 01/24/2007 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | |
| 01/26/2007 | NPPO - FINAL | ACONNOR | Approved | |
| 01/26/2007 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
| 01/27/2007 | RIGHT OF WAY - FINAL | MOTERO | Approved | PER EMAIL |
| 01/30/2007 | ENGINEERING - FINAL | MRUSSO | Approved | |
| 01/31/2007 | FIRE - FINAL | LTHOMAS | Approved | |
| 01/31/2007 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | |
| 01/31/2007 | FIRE SPKLR - UG PIPING FLUSH | LTHOMAS | Approved | |
| 01/31/2007 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | |
| 01/31/2007 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
| 01/31/2007 | FIRE - ALARM FINAL | LTHOMAS | Approved | |
| 02/01/2007 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection :* |
| 02/02/2007 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection :* |
| 02/02/2007 | U VALUE FOR WINDOW | AQUIROZ | Approved | IVRS - Inspection :* |