Permit Details

Status:
C of o
Type:
MULTI FAMILY NEW
Address NEW:
2550 E RIVER RD 13
Apply Date:
12/10/2001
Applicant:
N/A
Description:
NEW:APARTMENTS
Contractors:
  • LECHNER CONSTRUCTION INC ,

Permit Reviews

Permit Number - T01CM05969
Permit Status: C of o
Permit Description: NEW:APARTMENTS
Start Date Submittal Complete Date Status  
06/12/2003 3RD PARTY REVIEW-REVISION/OTHER 07/07/2003 COMPLETED Review Details
10/08/2002 RESUBMITTAL 10/08/2002 COMPLETED Review Details
12/12/2001 3RD PARTY REVIEW-COMMERCIAL 10/08/2002 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T01CM05969
Permit Status: C of o
Permit Description: NEW:APARTMENTS
Total Outstanding Activity Conditions - 1
Date Name
12/10/2001 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T01CM05969
Permit Description: NEW:APARTMENTS
Total Completed Inspections - 37
Date Description Inspector Results Comments
12/19/2002 PLUMBING - ROUGH, SOIL TRINIVJR Approved IVRS - Inspection 0000*
1.) SOIL WATER TEST IS OK
2.) BLDG. DRAIN IS STUBBED OUT @ TWO WAY C.O. ONLY.
3.) OK TO BACKFILL TRENCH.
02/03/2003 ELECTRIC - UFER RHOLLAND Approved IVRS - Inspection 0000*OK 2 - #4 TO REBAR.
02/03/2003 BUILDING PRE-SLAB AQUIROZ Approved IVRS - Inspection 0000*
02/19/2003 EXCAVATION/LAYOUT REBAR & ZON AQUIROZ Approved
05/05/2003 ROOF NAILING AMATHIES Approved IVRS - Inspection 0000*
05/05/2003 EXT METAL CLIPS/EXT SHEATHING AMATHIES Approved IVRS - Inspection 0000*
07/08/2003 PLUMBING - SEWER HCS CONNECT JSTANLEY Approved IVRS - Inspection 0000*
07/29/2003 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection 0000*
08/07/2003 ELECTRIC - ABOVE CEILING RHOLLAND Approved IVRS - Inspection 0000*
08/07/2003 ELECTRIC - INTERMEDIATE RHOLLAND Approved IVRS - Inspection 0000*/ 1) OK ROUGH ELECTRIC
08/08/2003 STUCCO MESH AQUIROZ Approved
08/25/2003 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection 0000*
08/25/2003 FRAMING AQUIROZ Approved IVRS - Inspection 0000*
03/17/2004 ELECTRIC - CABLE DROP MCAPISTR Approved IVRS - Inspection 0000*
04/14/2004 ELECTRIC - UNDERGROUND MCAPISTR Approved IVRS - Inspection 0000*
04/19/2004 ELECTRIC - TEMPORARY SERVICE MCAPISTR Approved IVRS - Inspection 0000*
04/20/2004 TEP CLEARANCE - AM JKOZUCH Approved
12/23/2005 BUILDING - PROGRESS SLONG Approved PAINT, TEXTURE, CARPETS, APPLIANCES, FIXTURES-PROGRESS OK
11/22/2006 MECHANICAL - FINAL JWEATHER Approved DEAN LEFT A MESSAGE ON MY VOICE MAIL TO CANCEL INSPECTION FOR MECH FINAL SCHEDULED FOR 11/24/06. WENT AHEAD AND REMOVED IT FROM CALENDAR SO IT WOULD NOT PRINT OUT ON 11/24/06
11/28/2006 ELECTRIC - FINAL CCLEMENS Approved IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
1. INSTALL FRESH BATTERIES IN SMOKE DETECTORS -
NEC 110.3B
2. RANGE ANTI-TIP BRACKETS NOT PROPERLY INSTALLED -
NEC 110.3B
3. FINISH EXTERIOR SITE LIGHTING
4. INSTALL BULBS CORRECT WATTAGE IN ALL FIXTURES
5. SHOWER TRIM REQUIRED IN SHOWER LIGHT - NEC 410.4
6. PROVIDE INSTALLATION INSTRCUTIONS FOR SMOKE DETECTORS IT APPEARS SOME MAY NOT BE CORRECTLY LOCATED (SAME MANUFACTURER OF SMOKES) -- 110.3B
7. SMOKE DETECTOR, LIGHTING AND RECEPTACLE WIRING IN BEDROOMS TO COMPLY WITH NEC 210.12B
8. PANEL DIRECTORY NOT CORRECTLY IDENTIFIED - NEC 408.4
9. TIGHTEN ANY LOOSE DEVICES AND REPLACE ANY CRACKED DEVICE COVERS.
10. TIGHTEN WATER HEATER GROUND
INSPECTION FOR THE INTERIOR OF UNIT #13103 ONLY CHECK FOR THESE AND OTHER CORRECTIONS THROUGHOUT SERVICE DISCONNECTS DO NOT DISCONNECT ALL UNGROUNDED CONDUCTORS IN STRUCTURE.
11/29/2006 PLUMBING - FINAL RMYERS Approved IVRS - Inspection :*
CALL IN AND HAVE APPROVED ALL REQUIRED INSPECTIONS
PRIOR TO CALLING INSPECTOR.
12/18/2006 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection :*
1. HAVE PLUMBER CHECK W & O ON TWO UNITS OK TO COVER
2. YARDWATER INSTALLED W/O INSPECTION
CONTRACTOR POTHOLED PIPING
CONNECTIONS LOOK OK
12/18/2006 PLUMBING - YARD WTR LINE/TEST RMYERS Approved IVRS - Inspection :*
01/24/2007 MECHANICAL - ABOVE CEILING JMILITEL Approved
01/26/2007 NPPO - FINAL ACONNOR Approved
01/26/2007 SIGN - FINAL JYBARRA Approved IVRS - Inspection :*
01/27/2007 RIGHT OF WAY - FINAL MOTERO Approved PER EMAIL
01/30/2007 ENGINEERING - FINAL MRUSSO Approved
01/31/2007 FIRE - FINAL LTHOMAS Approved
01/31/2007 FIRE SPKLR - UG, PIPING, HYDRO LTHOMAS Approved
01/31/2007 FIRE SPKLR - UG PIPING FLUSH LTHOMAS Approved
01/31/2007 FIRE SPKLR - OH PIPING & HYDRO LTHOMAS Approved
01/31/2007 FIRE SPKLR - FINAL LTHOMAS Approved
01/31/2007 FIRE - ALARM FINAL LTHOMAS Approved
02/01/2007 PLUMBING - ABOVE CEILING RMYERS Approved IVRS - Inspection :*
02/02/2007 BUILDING - FINAL AQUIROZ Approved IVRS - Inspection :*
02/02/2007 U VALUE FOR WINDOW AQUIROZ Approved IVRS - Inspection :*

Documents

File Name Document Type  
None DOCUMENTS VIEW
C OF O_02-05-2007.TIF CERT OF OCC VIEW