Permit: T01CM05969

Parcel: 10824013F


Addresses:

2550 E RIVER RD 13


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T01CM05969

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
12/18/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
1. HAVE PLUMBER CHECK W & O ON TWO UNITS OK TO COVER
2. YARDWATER INSTALLED W/O INSPECTION
CONTRACTOR POTHOLED PIPING
CONNECTIONS LOOK OK
12/14/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
HALF OF 1ST FLOOR TUBS OK
06/26/2003 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection 0000* 1) FIRST FLOOR TUBS ARE NOT SER. ONE OF THE BOXOUTS IS FULL OF WATER, SUGGESTING THERE MAY BE A LEAK. DRY OUT BOX AND RETEST 2) PVC DWC THRU ROOF ( 3 FLOOR ) OK 3) COPPER WATER PIPING OK 4) CLOSET FLANGES OK 5) 2ND & 3RD FLOOR TUBS- OK NEED TO SEE FIRST FLOOR TUBS SET & TESTED. 6) OK TO COVER ALL WALLS AND CEILINGS.
06/25/2003 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*/ 1) NO WATER TEST ON PVC 2) NO PRESSURE TEST ON COPPER 3) INSPECTION STOPPED
06/19/2003 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000* 1) WATER LINES MAY NOT CROSS OR RUN ABOVE AN ELECTRICAL SERVICE PANEL. 2) NO TUBS SET. 3) ALL HANGERS AND SUPPORTS TO BE IN ACCORDANCE TO TABLE 3-1 94UPC 4) ALL BLDGS TO BE VISIBLY NUMBERED 5) INSPECTION INCOMPLETE