Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
DUPLEX NEW
Apply Date:
11/05/2001
Applicant:
FURLOW ,
Description:
DUPLEX:TD#14-11-45
Contractors:
  • FURLOW ,

Permit Reviews

Permit Number - T01CM05473
Permit Status: Final
Permit Description: DUPLEX:TD#14-11-45
Start Date Submittal Complete Date Status  
11/05/2001 RESIDENTIAL BLDG/ZONING/FLOOD 11/05/2001 COMPLETED Review Details

Completed Inspections

Permit Status: Final
Permit Number: T01CM05473
Permit Description: DUPLEX:TD#14-11-45
Total Completed Inspections - 27
Date Description Inspector Results Comments
03/26/2002 PLUMBING - ROUGH, SOIL FMCCLURE Approved IVRS - Inspection 0000*
05/09/2002 ELECTRIC - UFER MCAPISTR Approved IVRS - Inspection 0000*
05/09/2002 ELECTRIC - UFER MCAPISTR Approved IVRS - Inspection 0000*
05/09/2002 ELECTRIC - UFER MCAPISTR Approved IVRS - Inspection 0000*
05/13/2002 BUILDING PRE-SLAB AQUIROZ Approved IVRS - Inspection 0000*
05/13/2002 EXCAVATION/LAYOUT REBAR & ZON AQUIROZ Approved IVRS - Inspection 0000*
11/06/2002 ROOF NAILING RSUBA Approved IVRS - Inspection 0000*
11/06/2002 EXT METAL CLIPS/EXT SHEATHING RSUBA Approved IVRS - Inspection 0000*
01/22/2003 U VALUE FOR WINDOW LHANLY Approved IVRS - Inspection 0000*
01/24/2003 ELECTRIC - INTERMEDIATE RMAJUTA Approved IVRS - Inspection 0000*
01/29/2003 FRAMING LHANLY Approved IVRS - Inspection 0000*
01/30/2003 PLUMBING - INTERMEDIATE TRINIVJR Approved IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK
2.) OVERHEAD WATER DISTRIBUTION IS OK
3.) OK FOR DRYWALL.
02/04/2003 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection 0000*OK FOR SHEET ROCK.
02/10/2003 STUCCO MESH LHANLY Approved IVRS - Inspection 0000*
03/06/2003 SHEET ROCK NAILING LHANLY Approved IVRS - Inspection 0000*
05/01/2003 ELECTRIC - CABLE DROP JORTA Approved IVRS - Inspection 0000*SENT TO TEP ON 5/2/03 AT 9:15AM OK TO CLEAR. USE RUST RESISTANT 1/4" HARDWARE SUCH AS LUG BOLTS TO SUPPORT CONDUIT ON 2 HOLE STRAP.
05/13/2003 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection 0000*
05/13/2003 ELECTRIC - FINAL RHOLLAND Approved IVRS - Inspection 0000*OK FINAL.
05/13/2003 ELECTRIC - TEMPORARY SERVICE RHOLLAND Approved IVRS - Inspection 0000*
05/15/2003 PERMIT FINALED TRINIVJR Approved
05/15/2003 PLUMBING - FINAL TRINIVJR Approved IVRS - Inspection 0000*1.) PLBG FINAL IS OK.
2.) OK FOR C OF O.
05/15/2003 PLUMBING - SEWER HCS CONNECT TRINIVJR Approved
05/15/2003 PLUMBING - GAS PRESSURE TEST TRINIVJR Approved
05/15/2003 PLUMBING - YARD WTR LINE/TEST TRINIVJR Approved
05/15/2003 ELECTRIC - UNDERGROUND RHOLLAND Approved
05/20/2003 BUILDING - FINAL HLEYVA Approved IVRS - Inspection 0000*OK FOR C OF O.
05/20/2003 STEM WALL/RETAINING WALL HLEYVA Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW