Permit: T01CM05386
Permit Details
Apply Date:
10/29/2001
Applicant:
ARCHITECTON
Description:
RESTAURANT 81' 5" x 29' 5" BUILDING, WOOD STUDS W/ STUCCO ,WOOD TRUSSES W/ WOOD DECKING
Contractors:
- B D & T INC.
Permit Reviews
Permit Number - T01CM05386
Permit Status: C of o
Permit Description: RESTAURANT 81' 5" x 29' 5" BUILDING, WOOD STUDS W/ STUCCO ,WOOD TRUSSES W/ WOOD DECKING
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/09/2002 | COMMERCIAL NEW | 05/21/2002 | COMPLETED |
| 04/09/2002 | SITE | 05/21/2002 | COMPLETED |
| 04/23/2002 | COMMERCIAL NEW | 08/01/2002 | COMPLETED |
| 06/27/2002 | SITE | 08/01/2002 | COMPLETED |
| 08/01/2002 | RESUBMITTAL | 08/08/2002 | COMPLETED |
| 10/12/2001 | SITE | 01/10/2002 | COMPLETED |
| 10/29/2001 | COMMERCIAL NEW | 01/10/2002 | COMPLETED |
Completed Inspections
Permit Status: C of o
Permit Number: T01CM05386
Permit Description: RESTAURANT 81' 5" x 29' 5" BUILDING, WOOD STUDS W/ STUCCO ,WOOD TRUSSES W/ WOOD DECKING
Total Completed Inspections - 35
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/06/2002 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) BLDG. DRAIN IS STUBBED OUT OF BLDG. ONLY 3.) NOTE: WILL REQUIRED A REVISED & APPROVED DRAIWING PRIOR TO INTERMEDIATE INSPECTION. 4.) OK FOR BACKFILL. |
| 09/06/2002 | ELECTRIC - UNDERGROUND | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 09/10/2002 | ELECTRIC - UFER | DSANTACR | Approved | IVRS - Inspection 0000* |
| 09/10/2002 | BUILDING PRE-SLAB | AMATHIES | Approved | IVRS - Inspection 0000* |
| 09/10/2002 | STEM WALL/RETAINING WALL | AMATHIES | Approved | IVRS - Inspection 0000* |
| 09/10/2002 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved | IVRS - Inspection 0000* |
| 09/18/2002 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 09/19/2002 | PLUMBING - SEWER HCS CONNECT | TRINIVJR | Approved | IVRS - Inspection 0000*4" BLDG. SEWER FROM TWO WAY C.O. TO HCS CONNECTION IS OK 2.) OK TO BACKFILL TRENCH. 3.) GREASE INTERCEPTOR HAS BEEN SET OK TO BACKFILL. |
| 09/25/2002 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection 0000*WANERD CONTR. ABOUT TEMP POWER FEED TO JOB TRAILOR, LAYING ON GROUND ACCROSS DRIVE WAY BURY LINE. |
| 09/26/2002 | EXT METAL CLIPS/EXT SHEATHING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 09/27/2002 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | IVRS - Inspection 0000*1.) WASTE & VENT SYSTEM IS OK 2.) SOIL WATER TEST IS OK 3.) OVERHEAD WATER DISTRIBUTION IS OK 4.) OK FOR DRYWALL UPON BLDG. INSPECTORS APPROVAL. 5.) GAS PRESSURE TEST IS OK NOTE 2" & 3/4" SUPPLY IS PARTIAL ONLY. |
| 10/01/2002 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
| 10/02/2002 | PLUMBING - YARD WTR LINE/TEST | TRINIVJR | Approved | IVRS - Inspection 0000*1.) FINAL CONNECTION TO WATER METER IS OK 2.) OK FOR BACKFILL. |
| 10/03/2002 | STUCCO MESH | AMATHIES | Approved | IVRS - Inspection 0000* |
| 10/14/2002 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection 0000*INSPECTED EXHAUST & SUPPLY DUCTS TO RESTROOMS OK TO COVER. |
| 10/14/2002 | PLUMBING - ABOVE CEILING | TRINIVJR | Approved | IVRS - Inspection 0000*1.) OVERHEAD GAS SYSTEM IN CEILING IS OK 2.) GAS PRESSURE TEST IS OK 3.) OK FOR GRID. |
| 10/18/2002 | MECHANICAL - HOODS | JMILITEL | Approved | IVRS - Inspection 0000*CONDENSATE DRAIN LINES DO NOT HAVE ADEQUATE SLOPE. PROVIDE MIN 1/8 PER FT. NEED TO SEE CONDENSATE FROM WALK IN COOLER. GREASE DUCT WRAP IS OK WILL CHECK CORRECTION ON FINAL. OK FOR CEILING TILES. |
| 10/18/2002 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection 0000* |
| 10/18/2002 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved | IVRS - Inspection 0000* |
| 10/22/2002 | MECHANICAL - TEMP PWR FOR TEST | JMILITEL | Approved | |
| 10/22/2002 | PLUMBING - TEMP POWER FOR TEST | TRINIVJR | Approved | 1.) PLBG FINAL IS OK 2.) OK FOR C OF O. |
| 10/22/2002 | ELECTRIC - TEMP POWER FOR TEST | MCAPISTR | Approved | |
| 10/22/2002 | BUILDING - TEMP POWER FOR TEST | AMATHIES | Approved | |
| 10/23/2002 | RIGHT OF WAY - FINAL | MOTERO | Approved | |
| 10/23/2002 | OUTDOOR LIGHTING FINAL | DSANTACR | Approved | IVRS - Inspection 0000*INSTALL PANEL SCHEDULES 2.) INSTALL GFCI RECEPT AT OUTLET OVER NORTH SINK. 3.) LABEL DISCONNECTS ON ROOF. |
| 10/24/2002 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection 0000* OK C OF O. |
| 10/28/2002 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000*OK FOR C OF O. |
| 10/28/2002 | SIGN - FINAL | DJOHNSTO | Approved | IVRS - Inspection 0000* |
| 10/28/2002 | LANDSCAPE - FINAL | PGILBERT | Approved | |
| 10/28/2002 | ENGINEERING - FINAL | JBRUCKME | Approved | |
| 10/28/2002 | FIRE - FINAL | LTHOMAS | Approved | OKAY C OF O. |
| 10/28/2002 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection 0000* |
| 10/29/2002 | PLUMBING - FINAL | TRINIVJR | Approved | |
| 10/29/2002 | PLUMBING - PROGRESS | TRINIVJR | Approved | |
| 10/29/2002 | PLUMBING - GAS PRESSURE TEST | TRINIVJR | Approved |