Permit Details

Status:
C of o
Type:
COMMERCIAL NEW
Address:
3455 E GRANT RD
Address NEW:
3455 E GRANT RD
Apply Date:
10/29/2001
Applicant:
ARCHITECTON
Description:
RESTAURANT 81' 5" x 29' 5" BUILDING, WOOD STUDS W/ STUCCO ,WOOD TRUSSES W/ WOOD DECKING
Contractors:
  • B D & T INC.

Permit Reviews

Permit Number - T01CM05386
Permit Status: C of o
Permit Description: RESTAURANT 81' 5" x 29' 5" BUILDING, WOOD STUDS W/ STUCCO ,WOOD TRUSSES W/ WOOD DECKING
Start Date Submittal Complete Date Status  
04/09/2002 COMMERCIAL NEW 05/21/2002 COMPLETED Review Details
04/09/2002 SITE 05/21/2002 COMPLETED Review Details
04/23/2002 COMMERCIAL NEW 08/01/2002 COMPLETED Review Details
06/27/2002 SITE 08/01/2002 COMPLETED Review Details
08/01/2002 RESUBMITTAL 08/08/2002 COMPLETED Review Details
10/12/2001 SITE 01/10/2002 COMPLETED Review Details
10/29/2001 COMMERCIAL NEW 01/10/2002 COMPLETED Review Details

Completed Inspections

Permit Status: C of o
Permit Number: T01CM05386
Permit Description: RESTAURANT 81' 5" x 29' 5" BUILDING, WOOD STUDS W/ STUCCO ,WOOD TRUSSES W/ WOOD DECKING
Total Completed Inspections - 35
Date Description Inspector Results Comments
09/06/2002 PLUMBING - ROUGH, SOIL TRINIVJR Approved IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) BLDG. DRAIN IS STUBBED OUT OF BLDG. ONLY 3.) NOTE: WILL REQUIRED A REVISED & APPROVED DRAIWING PRIOR TO INTERMEDIATE INSPECTION. 4.) OK FOR BACKFILL.
09/06/2002 ELECTRIC - UNDERGROUND MCAPISTR Approved IVRS - Inspection 0000*
09/10/2002 ELECTRIC - UFER DSANTACR Approved IVRS - Inspection 0000*
09/10/2002 BUILDING PRE-SLAB AMATHIES Approved IVRS - Inspection 0000*
09/10/2002 STEM WALL/RETAINING WALL AMATHIES Approved IVRS - Inspection 0000*
09/10/2002 EXCAVATION/LAYOUT REBAR & ZON AMATHIES Approved IVRS - Inspection 0000*
09/18/2002 ROOF NAILING AMATHIES Approved IVRS - Inspection 0000*
09/19/2002 PLUMBING - SEWER HCS CONNECT TRINIVJR Approved IVRS - Inspection 0000*4" BLDG. SEWER FROM TWO WAY C.O. TO HCS CONNECTION IS OK 2.) OK TO BACKFILL TRENCH. 3.) GREASE INTERCEPTOR HAS BEEN SET OK TO BACKFILL.
09/25/2002 ELECTRIC - INTERMEDIATE DSANTACR Approved IVRS - Inspection 0000*WANERD CONTR. ABOUT TEMP POWER FEED TO JOB TRAILOR, LAYING ON GROUND ACCROSS DRIVE WAY BURY LINE.
09/26/2002 EXT METAL CLIPS/EXT SHEATHING AMATHIES Approved IVRS - Inspection 0000*
09/27/2002 PLUMBING - INTERMEDIATE TRINIVJR Approved IVRS - Inspection 0000*1.) WASTE & VENT SYSTEM IS OK 2.) SOIL WATER TEST IS OK 3.) OVERHEAD WATER DISTRIBUTION IS OK 4.) OK FOR DRYWALL UPON BLDG. INSPECTORS APPROVAL. 5.) GAS PRESSURE TEST IS OK NOTE 2" & 3/4" SUPPLY IS PARTIAL ONLY.
10/01/2002 SHEET ROCK NAILING AMATHIES Approved IVRS - Inspection 0000*
10/02/2002 PLUMBING - YARD WTR LINE/TEST TRINIVJR Approved IVRS - Inspection 0000*1.) FINAL CONNECTION TO WATER METER IS OK 2.) OK FOR BACKFILL.
10/03/2002 STUCCO MESH AMATHIES Approved IVRS - Inspection 0000*
10/14/2002 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection 0000*INSPECTED EXHAUST & SUPPLY DUCTS TO RESTROOMS OK TO COVER.
10/14/2002 PLUMBING - ABOVE CEILING TRINIVJR Approved IVRS - Inspection 0000*1.) OVERHEAD GAS SYSTEM IN CEILING IS OK 2.) GAS PRESSURE TEST IS OK 3.) OK FOR GRID.
10/18/2002 MECHANICAL - HOODS JMILITEL Approved IVRS - Inspection 0000*CONDENSATE DRAIN LINES DO NOT HAVE ADEQUATE SLOPE. PROVIDE MIN 1/8 PER FT. NEED TO SEE CONDENSATE FROM WALK IN COOLER. GREASE DUCT WRAP IS OK WILL CHECK CORRECTION ON FINAL. OK FOR CEILING TILES.
10/18/2002 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection 0000*
10/18/2002 ELECTRIC - ABOVE CEILING DSANTACR Approved IVRS - Inspection 0000*
10/22/2002 MECHANICAL - TEMP PWR FOR TEST JMILITEL Approved
10/22/2002 PLUMBING - TEMP POWER FOR TEST TRINIVJR Approved 1.) PLBG FINAL IS OK 2.) OK FOR C OF O.
10/22/2002 ELECTRIC - TEMP POWER FOR TEST MCAPISTR Approved
10/22/2002 BUILDING - TEMP POWER FOR TEST AMATHIES Approved
10/23/2002 RIGHT OF WAY - FINAL MOTERO Approved
10/23/2002 OUTDOOR LIGHTING FINAL DSANTACR Approved IVRS - Inspection 0000*INSTALL PANEL SCHEDULES 2.) INSTALL GFCI RECEPT AT OUTLET OVER NORTH SINK. 3.) LABEL DISCONNECTS ON ROOF.
10/24/2002 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection 0000* OK C OF O.
10/28/2002 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection 0000*OK FOR C OF O.
10/28/2002 SIGN - FINAL DJOHNSTO Approved IVRS - Inspection 0000*
10/28/2002 LANDSCAPE - FINAL PGILBERT Approved
10/28/2002 ENGINEERING - FINAL JBRUCKME Approved
10/28/2002 FIRE - FINAL LTHOMAS Approved OKAY C OF O.
10/28/2002 BUILDING - FINAL AMATHIES Approved IVRS - Inspection 0000*
10/29/2002 PLUMBING - FINAL TRINIVJR Approved
10/29/2002 PLUMBING - PROGRESS TRINIVJR Approved
10/29/2002 PLUMBING - GAS PRESSURE TEST TRINIVJR Approved