Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T01CM05249
Permit Details
Apply Date:
10/19/2001
Applicant:
N/A
Description:
TI:RESTAURANT SUITE # 155
Contractors:
- DAKOTA BUILDERS INC ,
Permit Reviews
Permit Number - T01CM05249
Permit Status: C of o
Permit Description: TI:RESTAURANT SUITE # 155
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
10/19/2001 | COMMERCIAL TI | 11/20/2001 | COMPLETED |
12/11/2001 | REVISION | 12/11/2001 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T01CM05249
Permit Status: C of o
Permit Description: TI:RESTAURANT SUITE # 155
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
10/19/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T01CM05249
Permit Description: TI:RESTAURANT SUITE # 155
Total Completed Inspections - 26
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/21/2001 | PLUMBING - ROUGH, SOIL | JSTANLEY | Approved | IVRS - Inspection 0000*UNDER GROUND ONLY 10' TEST OK PLEASE PROVIDE APPROVED REVISED PLAN FOR NEW LOCATION OF FLOOR SINK & VENT WILL SEE THIS AT TOP OUT 10' TEST REQUIRED AT TOP OUT FOR WASTE & VENT FOR FIXTURES ABOVE FINISH FLOOR. |
12/05/2001 | FRAMING | EMONAHAN | Approved | IVRS - Inspection 0000* |
12/13/2001 | PLUMBING - INTERMEDIATE | JSTANLEY | Approved | IVRS - Inspection 0000*WALLS ONLY OK TO COVER WALLS ONLY. PLEASE PROVIDE CLEVIS HANGERS AS NEEDED ON ABS 4' O" ON CENTER, ALSO SEE WATER ON DRAWING PLAN CALLER FOR 1" TO WATER POINT OF CONNECTIONS 1 1/4 SEE PLAN FIELD VERIFY IF YOU NEED A PLAN REVISION PLEASE DO SO. |
12/14/2001 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | IVRS - Inspection 0000*1. HR. RATED CHASE IS OK DEPENDING ON EXHAUST DUCT SIZE CO ORDINATE W/ ARCHITED PLAN EXAMINER AND MECH. CONTR. |
12/14/2001 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection 0000*PARTIAL 1.) WALL ROUGH IN IS GOOD. |
12/17/2001 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
12/31/2001 | MECHANICAL - TEMP PWR FOR TEST | CWILLIAM | Approved | |
12/31/2001 | PLUMBING - GAS PRESSURE TEST | JSTANLEY | Approved | IVRS - Inspection 0000* |
12/31/2001 | ELECTRIC - TEMP POWER FOR TEST | RMAJUTA | Approved | |
12/31/2001 | ELECTRIC - ABOVE CEILING | RHOLLAND | Approved | IVRS - Inspection 0000*1.) SUPPORT M/C CABLE AS PER CODES 334 & 300-11 WITHIN 12" OF BOX AND INDEPENDANTLY OF CEILING WIRE 2.) PLEASE ATTACH FIXTURES TO GRID. 3.) STRAP CONDUIT ABOVE WASH AREA. SUPPORT IS IN BUT NOT TIED OFF OK TO CLEAR POWER FOR TESTING SUBJECT TO OTHER INSPECTION. HAVE A HAPPY NEW YEAR. |
12/31/2001 | BUILDING - TEMP POWER FOR TEST | EMONAHAN | Approved | IVRS - Inspection 0000* |
01/02/2002 | SIGN - FINAL | DJOHNSTO | Approved | IVRS - Inspection 0000* |
01/03/2002 | ENGINEERING - FINAL | DROBERTS | Approved | |
01/07/2002 | HEALTH DEPT - FINAL 724-7908 | HEALTH | Approved | |
01/07/2002 | MECHANICAL - FINAL | CWILLIAM | Approved | |
01/07/2002 | MECHANICAL - HOODS | CWILLIAM | Approved | |
01/07/2002 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | |
01/07/2002 | PLUMBING - FINAL | RMYERS | Approved | 1.) ALL CORRECTIONS MADE OK 2.) PLUMBING FINAL OK 3.) RPBP CERT ON FILE W/TUCSON WATER. 4.) OK FOR C OF O. PENDING ANY OTHER INSPECTION. |
01/07/2002 | PLUMBING - PROGRESS | RMYERS | Approved | |
01/07/2002 | PLUMBING - TEMP POWER FOR TEST | RMYERS | Approved | |
01/07/2002 | PLUMBING - ABOVE CEILING | RMYERS | Approved | |
01/07/2002 | ELECTRIC - FINAL | RMAJUTA | Approved | IVRS - Inspection 0000*9AM NOT READY MECH CONTRACTOR NOT ON SITE YET. |
01/07/2002 | ELECTRIC - FINAL | RMAJUTA | Approved | IVRS - Inspection 0999* |
01/07/2002 | BUILDING - FINAL | EMONAHAN | Approved | IVRS - Inspection 0000* |
01/10/2002 | PERMIT FINALED | ENGINEER | Approved | |
01/10/2002 | RIGHT OF WAY - FINAL | ENGINEER | Approved |