Permit: T01CM04496
Permit Details
Apply Date:
09/12/2001
Applicant:
FAMILY DOLLAR
Description:
RETAIL BLDG
Contractors:
- K S S CONSTRUCTION COMPANY ,
Completed Inspections
Permit Status: C of o
Permit Number: T01CM04496
Permit Description: RETAIL BLDG
Total Completed Inspections - 37
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/29/2002 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection 0000*1.) ABS DWV UNDERGROUND OK WATER TEST 10' ONE RISER OK 2.) TYPE K UNDER BLDG OK OK TO COVER. |
| 08/02/2002 | ELECTRIC - TEMPORARY POLE | RMAJUTA | Approved | IVRS - Inspection 0000*1.) UFER 20' 1/0 COPPER OK 2.) 2-2 PVC'S SERVICE TO TEP TRANS OK 2. -3/4"PVC INSIDE BLDG. AREA OK 2 - 1 1/4" PVC INSIDE TO OUTSIDE OK. |
| 08/02/2002 | ELECTRIC - UNDERGROUND | RMAJUTA | Approved | IVRS - Inspection 0000* |
| 08/02/2002 | ELECTRIC - UFER | RMAJUTA | Approved | IVRS - Inspection 0000* |
| 08/06/2002 | BUILDING - TEMP POWER FOR TEST | LHANLY | Approved | |
| 08/12/2002 | BUILDING PRE-SLAB | RSUBA | Approved | IVRS - Inspection 0000*HAVE THE SPECIAL INSPECTION REPORT ON SITE FOR THE 1ST LIFT ON THE MASONRY. ALSO GROUT IN 4' LIFTS. |
| 08/16/2002 | PLUMBING - TEMP POWER FOR TEST | RMYERS | Approved | |
| 08/16/2002 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection 0000* |
| 08/16/2002 | ELECTRIC - TEMP POWER FOR TEST | JORTA | Approved | |
| 08/16/2002 | STEM WALL/RETAINING WALL | LHANLY | Approved | IVRS - Inspection 0000* |
| 08/19/2002 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection 0000*1.) PLUMBING ABOVE CEILING OK 2.) REVIEWED REVISED APPROVED DRAWING FOR SEWER OK. |
| 08/19/2002 | ELECTRIC - CABLE DROP | JORTA | Approved | IVRS - Inspection 0000*TEMP POWER APPROVED SUBJECT TO LAST INSPECTOR AN SIGN OFF SHEET. |
| 08/19/2002 | ELECTRIC - ABOVE CEILING | JORTA | Approved | IVRS - Inspection 0000* |
| 08/20/2002 | RIGHT OF WAY - FINAL | LLOPEZ | Approved | |
| 08/20/2002 | MECHANICAL - TEMP PWR FOR TEST | CWILLIAM | Approved | IVRS - Inspection 0000*TEMP POWER TEST APPROVED. |
| 08/20/2002 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 08/20/2002 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 08/20/2002 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection 0000* |
| 08/20/2002 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection 0000* |
| 08/20/2002 | BUILDING ABOVE CEILING | LHANLY | Approved | IVRS - Inspection 0000* |
| 08/20/2002 | FRAMING | LHANLY | Approved | IVRS - Inspection 0000*HIGH STRENGTH BOLT TESTS REVIEWED APPROVED. |
| 08/20/2002 | FRAMING | LHANLY | Approved | IVRS - Inspection 0999*I NEED SPECIAL INSPECTION REPORTS. |
| 08/21/2002 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 08/21/2002 | PLUMBING - FINAL | RMYERS | Approved | 1.) CORRECTIONS MADE OK 2.) PLUMBING FINAL OK 3.) OK FOR C OF O PENDING ANY OTHER INSPECTIONS. |
| 08/22/2002 | U VALUE FOR WINDOW | LHANLY | Approved | IVRS - Inspection 0000* |
| 08/28/2002 | ELECTRIC - FINAL | JORTA | Approved | IVRS - Inspection 0000* |
| 08/28/2002 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection 0000* |
| 08/29/2002 | SIGN - FINAL | DJOHNSTO | Approved | IVRS - Inspection 0000* |
| 08/29/2002 | ENGINEERING - FINAL | DROBERTS | Approved | |
| 08/29/2002 | FIRE - FINAL | LTHOMAS | Approved | |
| 08/29/2002 | ELECTRIC - INTERMEDIATE | JORTA | Approved | |
| 08/29/2002 | SHEET ROCK NAILING | LHANLY | Approved | |
| 08/29/2002 | ROOF NAILING | LHANLY | Approved | |
| 08/29/2002 | EXT METAL CLIPS/EXT SHEATHING | LHANLY | Approved | |
| 08/29/2002 | EXCAVATION/LAYOUT REBAR & ZON | LHANLY | Approved | |
| 08/30/2002 | PERMIT FINALED | PGILBERT | Approved | |
| 08/30/2002 | LANDSCAPE - FINAL | PGILBERT | Approved |