Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 07/29/2002 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection 0000*1.) ABS DWV UNDERGROUND OK WATER TEST 10' ONE RISER OK 2.) TYPE K UNDER BLDG OK OK TO COVER. |
| 07/25/2002 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*1.) SEE P-1 RISER R-1:4" REQUIRES 2% SLOPE THROUGHOUT. 2.) SEE PLUMBING SPEC, REVISION DATED 7/24/02 ESPECIALLY CLOUDED AREA. ALL UNDERGROUND WATER PIPING SHALL BE TYPE K COPPER MINIMUM" TRANSITION TO PVC WATER SERVICE NOT ACCEPTABLE. |
| 07/23/2002 |
PLUMBING - ROUGH, SOIL |
|
Not ready for Inspection |
IVRS - Inspection 0000* NOT READY FOR INSPECTION. |