Permit: T01CM04469
Permit Details
Apply Date:
09/11/2001
Applicant:
N/A
Description:
RESTAURANT:NEW WIENERSCHNITZEL
Contractors:
- CANYON BUILDING AND DESIGN L L C
Permit Reviews
Permit Number - T01CM04469
Permit Status: C of o
Permit Description: RESTAURANT:NEW WIENERSCHNITZEL
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
09/11/2001 | COMMERCIAL NEW | 10/03/2001 | COMPLETED |
10/18/2001 | RESUBMITTAL | 10/19/2001 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T01CM04469
Permit Status: C of o
Permit Description: RESTAURANT:NEW WIENERSCHNITZEL
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
09/11/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T01CM04469
Permit Description: RESTAURANT:NEW WIENERSCHNITZEL
Total Completed Inspections - 36
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/25/2001 | ELECTRIC - TEMPORARY POLE | DSANTACR | Approved | IVRS - Inspection 0000*OK TO CLEAR TEMP POLE. OK CABLEDROP. RECALL FOR FINAL AFTER TIE IN. |
10/30/2001 | ELECTRIC - UNDERGROUND | MCAPISTR | Approved | IVRS - Inspection 0000* |
10/30/2001 | ELECTRIC - UFER | MCAPISTR | Approved | IVRS - Inspection 0000*1.) GRD RODS & BARE CU IN FOOTING OK. |
11/01/2001 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection 0000*1.) SOIL WATER TEST FOR GREASE LINE IS OK. 2.) NOTE: WILL REQUIRE A REVISED & APPROVED DRAWING ON WASTE & VENT SYSTEM & GREASE LINE PRIOR TO NEXT INSPECTION. 3.) OK TO BACKFILL TRENCH. 4.) ALL U.G. PIPE WRAP IS OK. |
11/02/2001 | BUILDING PRE-SLAB | AMATHIES | Approved | IVRS - Inspection 0000* |
11/13/2001 | PLUMBING - SEWER HCS CONNECT | TRINIVJR | Approved | IVRS - Inspection 0000*1.) SITE SEWER OK FROM HCS CONNECTION TO BACKWATER VALVE ONLY 2.) OK TO BACKFILL TRENCH. |
11/27/2001 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
11/29/2001 | STUCCO MESH | AMATHIES | Approved | |
11/29/2001 | FRAMING | AMATHIES | Approved | IVRS - Inspection 0000* |
12/05/2001 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) GAS PRESSURE TEST IS OK 3.) OVERHEAD WATER DISTRIBUTIONS OK 4.) CLOSET RINGS HAVE BEEN INSTALLED 5.) OK FOR DRYWALL. |
12/11/2001 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection 0000*REFER TO NOTE BELOW. PARTIAL BE ADVISED, THE GENERAL NOTES DO NOT PROVIDE FOR THE USE OF FLEXIBLE ELECTRICAL NON METALLIC CONDUIT (ENT). PLEASE PROVIDE THE ARCHITECTS OR ENGINEER OF RECORD LETTER APPROVING THE USE OF ENT AND FITTINGS. PLEASE PROVIDE MANUFACTURERS PRODUCT USE MANUAL OR LITERATURE FOR THE ENT. |
12/13/2001 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection 0000*PARTIAL INSPECTION ON MAKE UP AIR DUCTS IN WALLS O.K. TO COVER. |
12/17/2001 | REINFORCED MASONRY PRE-GROUT | AMATHIES | Approved | |
12/26/2001 | SHEET ROCK NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
01/18/2002 | MECHANICAL - TEMP PWR FOR TEST | JMILITEL | Approved | IVRS - Inspection 0000* |
01/18/2002 | PLUMBING - TEMP POWER FOR TEST | FMCCLURE | Approved | |
01/18/2002 | BUILDING - TEMP POWER FOR TEST | AMATHIES | Approved | IVRS - Inspection 0000* |
01/22/2002 | ELECTRIC - TEMP POWER FOR TEST | DSANTACR | Approved | IVRS - Inspection 0000*TEMP POWER OK SUBJECT TO BOND POSTING. OK TO CLEAR TEMP POWER WHEN BOND POSTED. |
01/23/2002 | ELECTRIC - CABLE DROP | DSANTACR | Approved | IVRS - Inspection 0000* |
01/30/2002 | MECHANICAL - HOODS | JMILITEL | Approved | IVRS - Inspection 0000* |
02/01/2002 | PLUMBING - FINAL | TRINIVJR | Approved | IVRS - Inspection 0000*1.) PLBG FINAL OK 2.) OK FOR C OF O. 2.) MUST POST ANZEL VALVE LOCATION ON CEILING TILE WITH PERMANET TAPE OR PAINT. |
02/05/2002 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved | IVRS - Inspection 0000* |
02/06/2002 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000*1.) HOOK UP ELECTRICAL TO EXHAUST FANS. 2.) THE UNION IN GAS LINE TO AC 2 MUST BE PRECEDED BY THE GAS SHUT OFF VALVE. 3.) PAINT ALL EXPOSED BLACK IRON O ROOF. ALL CORRECTIONS HAVE BEEN MADE OK FOR C OF O. |
02/11/2002 | ENGINEERING - FINAL | DROBERTS | Approved | |
02/12/2002 | HEALTH DEPT - FINAL 724-7908 | SBROWNIN | Approved | |
02/22/2002 | PERMIT FINALED | PWHIDDON | Approved | |
02/22/2002 | RIGHT OF WAY - FINAL | PWHIDDON | Approved | |
02/22/2002 | SIGN - FINAL | JYBARRA | Approved | |
02/22/2002 | LANDSCAPE - FINAL | PGILBERT | Approved | |
02/22/2002 | ELECTRIC - FINAL | DSANTACR | Approved | |
02/22/2002 | ELECTRIC - CONSTRUCTION POWER | DSANTACR | Approved | |
02/22/2002 | ELECTRIC - TEMPORARY SERVICE | DSANTACR | Approved | |
02/22/2002 | BUILDING - FINAL | AMATHIES | Approved | |
02/22/2002 | BUILDING ABOVE CEILING | AMATHIES | Approved | |
02/22/2002 | STEM WALL/RETAINING WALL | AMATHIES | Approved | |
02/22/2002 | EXCAVATION/LAYOUT REBAR & ZON | AMATHIES | Approved |