Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T01CM04469
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/01/2002 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000*1.) PLBG FINAL OK 2.) OK FOR C OF O. 2.) MUST POST ANZEL VALVE LOCATION ON CEILING TILE WITH PERMANET TAPE OR PAINT. | |
01/29/2002 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1.) H.C. LAVATORY NOT TO ADA SPECS AND APPROVED DRAWINGS 2.) ALL INDIRECT WASTE MUST HAVE A 1" AIR BREAK. 3.) MUST CAULK ALL FIXTURES (MOP SINK). 4.) MUST FINAL CONNECT GAS TO A.C. UNIT. 5.) ICE MACHINE REQUIRES A BACKFLOW PREVENTER. 6.) MUST TEST & CERIFY ALL BACKFLOW PREVENTERS. 7.) HOSE BIBS REQUIRES VACCUM BREAKERS 8.) MUST EXTEND 3" VTR 2" ABOVE INTAKE OF MAKE UP AIR UNIT 9.) TRIPLE COMPARTMENT SINK REQUIRES SLIP 10.) TRAP SIZE MUST BE THE SMAE SIZE AS TRAP ARM ON TRIPLE COMT. SINK |