Permit Details

Status:
C of o
Type:
MULTI FAMILY NEW
Address NEW:
1102 E HALCYON RD #01
Apply Date:
07/31/2001
Applicant:
CAVALLINO CONSTRUCTION
Description:
MFR:TD#14-97-72
Contractors:
  • CAVALLINO CONSTRUCTION

Permit Reviews

Permit Number - T01CM03750
Permit Status: C of o
Permit Description: MFR:TD#14-97-72
Start Date Submittal Complete Date Status  
12/12/2001 REVISION 01/11/2002 COMPLETED Review Details
12/20/2001 REVISION 12/26/2001 COMPLETED Review Details

Completed Inspections

Permit Status: C of o
Permit Number: T01CM03750
Permit Description: MFR:TD#14-97-72
Total Completed Inspections - 29
Date Description Inspector Results Comments
08/09/2001 PLUMBING - SEWER HCS CONNECT JSTANLEY Approved IVRS - Inspection 0000*
08/09/2001 PLUMBING - ROUGH, SOIL JSTANLEY Approved IVRS - Inspection 0000*TEST OK PROVIDE REVISED PLANS/WATER UNDER SUB OK.
08/15/2001 ELECTRIC - UFER RHOLLAND Approved IVRS - Inspection 0000*OK UFER.
08/15/2001 BUILDING PRE-SLAB EMONAHAN Approved IVRS - Inspection 0000*
08/15/2001 EXCAVATION/LAYOUT REBAR & ZON EMONAHAN Approved IVRS - Inspection 0000*
09/14/2001 ELECTRIC - TEMPORARY SERVICE RHOLLAND Approved IVRS - Inspection 0000*
09/14/2001 ELECTRIC - CABLE DROP RHOLLAND Approved IVRS - Inspection 0000*
09/24/2001 MECHANICAL - ABOVE CEILING CWILLIAM Approved IVRS - Inspection 0000*
09/24/2001 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection 0000*
09/24/2001 PLUMBING - TEMP POWER FOR TEST JSTANLEY Approved
09/24/2001 EXT METAL CLIPS/EXT SHEATHING EMONAHAN Approved IVRS - Inspection 0000*
09/27/2001 BUILDING - TEMP POWER FOR TEST EMONAHAN Approved
10/04/2001 PLUMBING - GAS PRESSURE TEST JSTANLEY Approved
10/04/2001 PLUMBING - ABOVE CEILING JSTANLEY Approved
10/04/2001 PLUMBING - INTERMEDIATE JSTANLEY Approved
10/15/2001 ELECTRIC - ABOVE CEILING DSANTACR Approved IVRS - Inspection 0000*
10/15/2001 ELECTRIC - INTERMEDIATE DSANTACR Approved IVRS - Inspection 0000*
10/25/2001 STUCCO MESH EMONAHAN Approved IVRS - Inspection 0000*
10/25/2001 FRAMING EMONAHAN Approved IVRS - Inspection 0000*
11/01/2001 SHEET ROCK NAILING EMONAHAN Approved IVRS - Inspection 0000*
12/05/2001 ELECTRIC - TEMP POWER FOR TEST RMAJUTA Approved
12/07/2001 MECHANICAL - TEMP PWR FOR TEST JMILITEL Approved
12/18/2001 MECHANICAL - FINAL CWILLIAM Approved
12/28/2001 SIGN - FINAL JYBARRA Approved IVRS - Inspection 0000*
12/28/2001 PLUMBING - FINAL JSTANLEY Approved IVRS - Inspection 0000*
12/28/2001 PLUMBING - YARD WTR LINE/TEST JSTANLEY Approved IVRS - Inspection 0000*REVISED PLAN CALLER FOR 1 BACKFLOW DEVICES 3/4 HAS BEEN INSTALLED #12 ON APPROVED REVISED PLAN NOT INSTALLED AT THIS TIME CHECK CODE ON BACKFLOW DEVICE INSTALLATION #PROVIDE APPROVED COVER FOR SEWER CO. PROVIDE TESTING ON BACK FLOW DEVICES.
12/28/2001 BUILDING - FINAL EMONAHAN Approved IVRS - Inspection 0000*
12/28/2001 ROOF NAILING EMONAHAN Approved IVRS - Inspection 0000*
12/30/2001 ELECTRIC - FINAL RHOLLAND Approved IVRS - Inspection 0000*1.) PLEASE CONNECT GROUNDING EQUIPMENT CONDUCTOR FOR BATH FIXTURE AND MAKE UP AND DIRECTIONS AS PER MANUFACTURE #1,,#3. 2.) SWITCHES TO BE GROUNDED AS PER CODE 380-9. 3.) I CAN NOT VERIFY IF FURANCE HAS THERMAL PROTECTION FOR MOTOR. IF NOT AND OVER CURRENT PROTECTION WILL NEED TO BE PROVIDED AT THE UNIT (SAU). 4.) PLEASE OPEN HOLE AT DISHWASHER/DISPOSAL PLUG FOR ACCESS ALL UNITS.5.) PLEASE PROVIDE FOR CLEANRENCE FO LIGHT FIXTURE IN CLOSET 410-8(1)
6.) A/C UNIT DISCONNECTS NEED TO BE LABELED 7.) EXPOSED ROMEX/UF IN FRONT OF BUILDING 8.) PLEASE PROVIDE ACCESS TO ROOF.