Permit: T01CM03123
Permit Details
Apply Date:
06/22/2001
Applicant:
J R TUTTLE CO
Description:
NEW:BAKERY
Contractors:
- J R TUTTLE CO
Permit Reviews
Permit Number - T01CM03123
Permit Status: C of o
Permit Description: NEW:BAKERY
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/23/2002 | REVISION | 02/20/2002 | COMPLETED |
| 06/22/2001 | COMMERCIAL NEW | 07/26/2001 | COMPLETED |
| 07/27/2001 | RESUBMITTAL | 07/27/2001 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T01CM03123
Permit Status: C of o
Permit Description: NEW:BAKERY
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/22/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T01CM03123
Permit Description: NEW:BAKERY
Total Completed Inspections - 30
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/15/2001 | ELECTRIC - CONSTRUCTION POWER | MCAPISTR | Approved | |
| 08/15/2001 | ELECTRIC - TEMPORARY SERVICE | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 08/17/2001 | ELECTRIC - UFER | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 08/17/2001 | EXCAVATION/LAYOUT REBAR & ZON | LHANLY | Approved | IVRS - Inspection 0000*PARITAL SITEWALL. |
| 08/21/2001 | STEM WALL/RETAINING WALL | DWITT | Approved | IVRS - Inspection 0000* |
| 08/30/2001 | PLUMBING - SEWER HCS CONNECT | FMCCLURE | Approved | IVRS - Inspection 0000* |
| 08/30/2001 | PLUMBING - YARD WTR LINE/TEST | FMCCLURE | Approved | IVRS - Inspection 0000* |
| 08/30/2001 | PLUMBING - ROUGH, SOIL | FMCCLURE | Approved | IVRS - Inspection 0000* |
| 09/13/2001 | ELECTRIC - UNDERGROUND | RMAJUTA | Approved | IVRS - Inspection 0000*ALL UNDERGROUND WITHIN STRUCTURE. |
| 09/18/2001 | BUILDING PRE-SLAB | DWITT | Approved | IVRS - Inspection 0000* |
| 10/10/2001 | REINFORCED MASONRY PRE-GROUT | DWITT | Approved | IVRS - Inspection 0000* |
| 11/02/2001 | EXT METAL CLIPS/EXT SHEATHING | DWITT | Approved | IVRS - Inspection 0000* |
| 11/27/2001 | PLUMBING - GAS PRESSURE TEST | FMCCLURE | Approved | IVRS - Inspection 0000* |
| 11/27/2001 | PLUMBING - INTERMEDIATE | FMCCLURE | Approved | IVRS - Inspection 0000* |
| 11/27/2001 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection 0000*WALL ROUGH IN OK. |
| 11/27/2001 | FRAMING | DWITT | Approved | IVRS - Inspection 0000* |
| 12/03/2001 | SHEET ROCK NAILING | DWITT | Approved | |
| 12/20/2001 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | NOT READY |
| 12/20/2001 | ELECTRIC - ABOVE CEILING | MCAPISTR | Approved | IVRS - Inspection 0000*1.)MAIN SERVICE & SEATING 2.) OFFICE. |
| 01/18/2002 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection 0000*OK TO COVER ALL CEILINGS. |
| 01/24/2002 | FIRE - FINAL | FIRE | Approved | |
| 01/24/2002 | FIRE SPKLR - FINAL | FIRE | Approved | |
| 01/26/2002 | PLUMBING - FINAL | FMCCLURE | Approved | IVRS - Inspection 0000*OK FOR TEMP C OF O |
| 01/31/2002 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000*ALL CORRECTIONS HAVE BEEN MADE FOR C OF O. |
| 01/31/2002 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection 0000* |
| 02/01/2002 | ENGINEERING - FINAL | DROBERTS | Approved | |
| 02/01/2002 | ELECTRIC - FINAL | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 02/04/2002 | BUILDING - FINAL | DWITT | Approved | IVRS - Inspection 0000* |
| 02/19/2002 | RIGHT OF WAY - FINAL | DLEE | Approved | APPROVED FOR C OF O |
| 02/20/2002 | PERMIT FINALED | AMATHIES | Approved |