Permit: T01CM02578
Permit Details
Apply Date:
05/29/2001
Applicant:
PAUL HUBBLE
Description:
ADDITION:MASTER BEDROOM/FAMILYROOM/BATHROOM
Contractors:
- SANDIA DEVELOPMENT INC ,
Permit Reviews
Permit Number - T01CM02578
Permit Status: Final
Permit Description: ADDITION:MASTER BEDROOM/FAMILYROOM/BATHROOM
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/29/2001 | RESIDENTIAL BLDG/ZONING/FLOOD/WWM | 06/20/2001 | COMPLETED |
| 07/25/2001 | RESUBMITTAL | 07/30/2001 | COMPLETED |
| 08/08/2001 | RESUBMITTAL | 08/17/2001 | COMPLETED |
| 08/17/2001 | RESUBMITTAL | 08/24/2001 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T01CM02578
Permit Status: Final
Permit Description: ADDITION:MASTER BEDROOM/FAMILYROOM/BATHROOM
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/29/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T01CM02578
Permit Description: ADDITION:MASTER BEDROOM/FAMILYROOM/BATHROOM
Total Completed Inspections - 14
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/30/2001 | PLUMBING - SEWER HCS CONNECT | FGREER | Approved | IVRS - Inspection 0000* |
| 08/30/2001 | PLUMBING - YARD WTR LINE/TEST | FGREER | Approved | IVRS - Inspection 0000* |
| 08/30/2001 | PLUMBING - ROUGH, SOIL | FGREER | Approved | IVRS - Inspection 0000* |
| 09/10/2001 | ELECTRIC - SERVICE RELOCATION | EDURAZO | Approved | |
| 09/28/2001 | ELECTRIC - TEMPORARY SERVICE | JRIVA | Approved | IVRS - Inspection 0000* |
| 09/28/2001 | ELECTRIC - CABLE DROP | JRIVA | Approved | IVRS - Inspection 0000* |
| 10/02/2001 | REINFORCED MASONRY PRE-GROUT | JRIVA | Approved | IVRS - Inspection 0000* |
| 12/13/2001 | ROOF NAILING | JRIVA | Approved | IVRS - Inspection 0000* |
| 02/05/2002 | FRAMING | JRIVA | Approved | IVRS - Inspection 0999*/ 1) 5080 WINDOW HEADER AND STUDS MISSING 2) FURR WALL NOT SECURE BY 5050. FHA STRAPS REQUIRE 6 NAILS EACH END 3) FIRE BLOCK NORTH WALL BELOW EXISTING SILL PLATE SEE PAGE 36 BELOW 4) FIRE BLOCK STAIRS 5) SHIM HEADER TO TOP PLATE AT FRENCH DOOR 6) FIRE BLOCK DUCT CHASE AT FLOOR 7) FIRE BLOCK CHIMNEY AND TIGHTEN OFF SET ELBOW STRAPS (3) 8) FIRE BLCOK FURRED WALL 2ND FLOOR 9) SHOWER VALVES NOT INSTALLED 10) TUB NOT IN 11) WIRES NOT ALLOWED TO BE EDGE NAILED EAST OF BAY WINDOW 12) GAS LINE MUST BE ELECTRICALLY BONDED 13) PLAN CALLS FOR HU SERIES HANGER MIT SERVICES USED. REVISE PLAN |
| 02/06/2002 | MECHANICAL - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection 0000* |
| 02/06/2002 | PLUMBING - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection 0000* |
| 02/06/2002 | ELECTRIC - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection 0000* |
| 02/13/2002 | SHEET ROCK NAILING | HPEDROZA | Approved | IVRS - Inspection 0000*/ 1) EXCEPT SHOWER ARE IN MASTER AND MECHANICAL ROOM AREA SEE COMMENT #1 DTD 2/6/02 |
| 06/21/2002 | PERMIT FINALED | DBRITO | Approved |