Inspection Status: Denied
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/05/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) 5080 WINDOW HEADER AND STUDS MISSING 2) FURR WALL NOT SECURE BY 5050. FHA STRAPS REQUIRE 6 NAILS EACH END 3) FIRE BLOCK NORTH WALL BELOW EXISTING SILL PLATE SEE PAGE 36 BELOW 4) FIRE BLOCK STAIRS 5) SHIM HEADER TO TOP PLATE AT FRENCH DOOR 6) FIRE BLOCK DUCT CHASE AT FLOOR 7) FIRE BLOCK CHIMNEY AND TIGHTEN OFF SET ELBOW STRAPS (3) 8) FIRE BLCOK FURRED WALL 2ND FLOOR 9) SHOWER VALVES NOT INSTALLED 10) TUB NOT IN 11) WIRES NOT ALLOWED TO BE EDGE NAILED EAST OF BAY WINDOW 12) GAS LINE MUST BE ELECTRICALLY BONDED 13) PLAN CALLS FOR HU SERIES HANGER MIT SERVICES USED. REVISE PLAN |