Permit Details

Status:
C of o
Type:
COMMERCIAL NEW
Address:
3301 N FREEWAY
Address NEW:
3301 N FREEWAY
Apply Date:
03/28/2001
Applicant:
N/A
Description:
COMERCIAL METAL BUILDING:NEW
Architects:
  • FENECK, JOHN
Contractors:
  • HALBERT BROS INC ,

Permit Reviews

Permit Number - T01CM01513
Permit Status: C of o
Permit Description: COMERCIAL METAL BUILDING:NEW
Start Date Submittal Complete Date Status  
07/11/2001 3RD PARTY REVIEW-COMMERCIAL 08/28/2001 COMPLETED Review Details
08/14/2001 SITE 08/23/2001 COMPLETED Review Details
08/24/2001 RESUBMITTAL 08/28/2001 COMPLETED Review Details

Completed Inspections

Permit Status: C of o
Permit Number: T01CM01513
Permit Description: COMERCIAL METAL BUILDING:NEW
Total Completed Inspections - 26
Date Description Inspector Results Comments
09/24/2001 PLUMBING - SEWER HCS CONNECT JSTANLEY Approved IVRS - Inspection 0000*PARTIAL ON 03055 FROM 4" CO - 2" BRANCH.
09/24/2001 PLUMBING - ROUGH, SOIL JSTANLEY Approved IVRS - Inspection 0000*UNDERGROUND ROUGH ONLY WILL REQUIRE 10' TEST AT TOP OUT RISER/ONLY AT THIS TIME.
10/02/2001 ELECTRIC - UFER RHOLLAND Approved IVRS - Inspection 0000*
10/04/2001 BUILDING PRE-SLAB EMONAHAN Approved IVRS - Inspection 0000$AP REMAINING 3/4 OK.
11/14/2001 ELECTRIC - UNDERGROUND RHOLLAND Approved OK 1-4" PVC PRIMARY BUILDING OUT TO TRANSFORMER. OK 1-4" PVC PHONE.
11/20/2001 PLUMBING - YARD WTR LINE/TEST JSTANLEY Approved IVRS - Inspection 0000*
11/20/2001 PLUMBING - ABOVE CEILING JSTANLEY Approved IVRS - Inspection 0000*
11/20/2001 PLUMBING - INTERMEDIATE JSTANLEY Approved IVRS - Inspection 0000*MIDSTORY ANCHOR/INSTALL T & P LINE & DRAIN PAN LINE. TEST ON WASTE VENTS & COPPER OK OK TO DRYWALL.
11/20/2001 FRAMING EMONAHAN Approved IVRS - Inspection 0000*
11/26/2001 ELECTRIC - INTERMEDIATE RHOLLAND Approved IVRS - Inspection 0000*OK SOUTH WALL WEAR HOUSE.
12/03/2001 SHEET ROCK NAILING EMONAHAN Approved IVRS - Inspection 0000*
12/03/2001 EXCAVATION/LAYOUT REBAR & ZON EMONAHAN Approved IVRS - Inspection 0000*
01/10/2002 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection 0000*
01/10/2002 MECHANICAL - ABOVE CEILING CWILLIAM Approved IVRS - Inspection 0000*
01/10/2002 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection 0000*
01/11/2002 PLUMBING - FINAL JSTANLEY Approved IVRS - Inspection 0000*FINAL OK S.T.O.I.
01/14/2002 ELECTRIC - ABOVE CEILING RHOLLAND Approved IVRS - Inspection 0000*OK TO TILE.
01/24/2002 ELECTRIC - FINAL RHOLLAND Approved IVRS - Inspection 0000*OK FINAL SUBJECT TO OTHER INSPECTIONS.
01/24/2002 ELECTRIC - CABLE DROP RHOLLAND Approved IVRS - Inspection 0000*
01/25/2002 BUILDING - FINAL AMATHIES Approved IVRS - Inspection 0000*
01/25/2002 BUILDING ABOVE CEILING AMATHIES Approved
03/05/2002 SIGN - FINAL JYBARRA Approved
03/12/2002 ENGINEERING - FINAL DROBERTS Approved THE FINAL GRADING INSPECTION WILL NOT BE COMPLETED AT THIS TIME. THIS PROJECT HAS BEEN PHASED INTO 3 SEPERATE PHASES, TO BE COMPLETED AT VARIOUS DATES. THE FINAL GRADING INSPECTION WILL NEED TO BE COMPLETED PRIOR TO THE RELEASE OF THE LAST C OF O FOR THIS SITE.
03/21/2002 PERMIT FINALED LTHOMAS Approved
03/21/2002 FIRE SPKLR - UG PIPING FLUSH LTHOMAS Approved
03/21/2002 FIRE SPKLR - UG, PIPING, HYDRO LTHOMAS Approved