Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
2703 E 6TH ST
Address NEW:
2703 E 6TH ST
Apply Date:
10/23/2000
Applicant:
PARTAGAS RAUL R & MARISELA CP/RS
Description:
INSTALL:ADDITIONAL LIGHT FIXTURES

Permit Reviews

Permit Number - T00EL02485
Permit Status: Expired
Permit Description: INSTALL:ADDITIONAL LIGHT FIXTURES
Start Date Submittal Complete Date Status  
10/23/2000 ELECTRICAL 10/23/2000 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T00EL02485
Permit Status: Expired
Permit Description: INSTALL:ADDITIONAL LIGHT FIXTURES
Total Outstanding Activity Conditions - 1
Date Name
10/23/2000 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T00EL02485
Permite Description: INSTALL:ADDITIONAL LIGHT FIXTURES
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
09/23/2002 ELECTRIC - FINAL N/A Denied IVRS - Inspection 0245*1.) ROMEX MUST BE PROPERLY TERMINATED INTO PANCAKE BOX, ONLY 1 14/2 ALLOWED PER CODE SEE 370-4, 370-17, 370-16A. 2.) BOXES TOBE GROUNDED 250-148, 370-4 NEC. 3.) ELECTRICAL TAPE NOT APPROVED. 4.) FOR SPLICES ON BRANCH CIRCUITS, USE LISTED WIRE NUTS OR OTHER APPROVED METHOD. 110-3,110-12,90-4 NEC.

Completed Inspections

Permit Status: Expired
Permit Number: T00EL02485
Permit Description: INSTALL:ADDITIONAL LIGHT FIXTURES
Total Completed Inspections - 1
Date Description Inspector Results Comments
04/17/2001 ELECTRIC - INTERMEDIATE RMAJUTA Approved IVRS - Inspection 0000*INSTALL FIXTURE MUST COVER ENTIRE PANCAKE BOX.

Documents

File Name Document Type  
None DOCUMENTS VIEW