2703 E 6TH ST


Inspection Status: Denied

Inspection History: ELECTRIC - FINAL

Permit Number - T00EL02485

Inspection Description - ELECTRIC - FINAL

Inspection Status - Denied

Date Description Inspector Results Comments
09/23/2002 ELECTRIC - FINAL Denied IVRS - Inspection 0245*1.) ROMEX MUST BE PROPERLY TERMINATED INTO PANCAKE BOX, ONLY 1 14/2 ALLOWED PER CODE SEE 370-4, 370-17, 370-16A. 2.) BOXES TOBE GROUNDED 250-148, 370-4 NEC. 3.) ELECTRICAL TAPE NOT APPROVED. 4.) FOR SPLICES ON BRANCH CIRCUITS, USE LISTED WIRE NUTS OR OTHER APPROVED METHOD. 110-3,110-12,90-4 NEC.
09/12/2001 ELECTRIC - FINAL Denied IVRS - Inspection 0245*NOTES 1.) NEED J-BOXES BEHIND FIXTURES.
09/11/2001 ELECTRIC - FINAL Denied IVRS - Inspection 0245*KNOCKED ON DOOR, NO ANSWER. NOT SURE WHICH LIGHT FIXTURES TO INSPECT, NO PLANS.