Permit: T00CM04670
Permit Details
Status:
Final
Type:
SINGLE FAMILY ALTERATION
Address:
826 E ALTURAS ST
Address NEW:
826 E ALTURAS ST
Apply Date:
09/19/2000
Applicant:
METRO PERMIT EXPRESS, INC
Description:
REMODEL:MASTER BEDROOM -DOUBLE FEE
Permit Reviews
Permit Number - T00CM04670
Permit Status: Final
Permit Description: REMODEL:MASTER BEDROOM -DOUBLE FEE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/19/2000 | 3RD PARTY REVIEW-RESIDENTIAL | 02/15/2001 | COMPLETED |
Completed Inspections
Permit Status: Final
Permit Number: T00CM04670
Permit Description: REMODEL:MASTER BEDROOM -DOUBLE FEE
Total Completed Inspections - 17
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/11/2000 | PLUMBING - SEWER HCS CONNECT | JRIVA | Approved | IVRS - Inspection 0000* |
| 12/11/2000 | PLUMBING - ROUGH, SOIL | JRIVA | Approved | IVRS - Inspection 0000* |
| 12/26/2000 | PLUMBING - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection 0000* |
| 12/26/2000 | ROOF NAILING | JRIVA | Approved | IVRS - Inspection 0000*/1. DOUBLE 2 X 4 POST CANNOT BE SPLICED. 2. UNTREATED WOOD CANNOT BE IN CONTACT WITH CONCRETE. 3. PLAN CALLS FOR 2 X 8 AT 16" O.C. SPACED AT 24" O.C. IN 6 FEET OF ADDN. 4. UNTREATED WOOD CANNOT BE WIHTIN 6" OF SOIL. 5. WIRES WITHIN 1 1/4 OF SURFACE. 6. ELECTRIC REQUIRES BUSHINGS AT METAL STUDY. 7. INADEQUATE NATURAL LITE. 300 SF HAS 20 SF NOW. 8. NO OTHER ELECT OUTLETS ALLOWED ON BATHROOM GFCI. 9. BATHROOM MUST BE 20 AMP TO GFC 12 GAUGE LINE. 10. ELECT CIRCUIT FOR HEAT PUMP. OK TO INSULATE AND DRYWALL ALL BUT BATH N. WALL AND MBR N. WALL/ELECT AND POST. |
| 12/26/2000 | BUILDING PRE-SLAB | JRIVA | Approved | IVRS - Inspection 0000* |
| 12/28/2000 | ELECTRIC - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection 0000* |
| 12/28/2000 | FRAMING | JRIVA | Approved | IVRS - Inspection 0000*/1. ITEMS FROM 12-26-00 OPEN 6, 7, 10, 11,12, 13, 14 OK TO DRYWALL ALL BUT N. WALL OF BATH. |
| 01/11/2001 | SHEET ROCK NAILING | JRIVA | Approved | IVRS - Inspection 0000* |
| 02/22/2001 | MECHANICAL - ABOVE CEILING | JRIVA | Approved | IVRS - Inspection 0000* |
| 02/22/2001 | PLUMBING - ABOVE CEILING | JRIVA | Approved | IVRS - Inspection 0000* |
| 02/22/2001 | ELECTRIC - ABOVE CEILING | JRIVA | Approved | IVRS - Inspection 0000* |
| 02/22/2001 | BUILDING ABOVE CEILING | JRIVA | Approved | IVRS - Inspection 0000* |
| 02/27/2001 | PERMIT FINALED | JRIVA | Approved | |
| 02/27/2001 | MECHANICAL - FINAL | JRIVA | Approved | IVRS - Inspection 0000* |
| 02/27/2001 | PLUMBING - FINAL | JRIVA | Approved | IVRS - Inspection 0000* |
| 02/27/2001 | ELECTRIC - FINAL | JRIVA | Approved | IVRS - Inspection 0000* |
| 02/27/2001 | BUILDING - FINAL | JRIVA | Approved | IVRS - Inspection 0000* |