Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 02/27/2001 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 02/23/2001 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/NO ACCESS NEXT FAILURE WILL BE CHARGED A REINSPECTION FEE. |
| 02/22/2001 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/1. OPEN NEUTRAL ON AN OUTLET BELOW HEAT PUMP. 2. LIGHT FIXTURE NOT ALLOWED WITHIN 12" OF CLOSET SHELF. 3. BARE BULB LIGHT FIXTURES NOT ALLOWED IN CLOSETS. 4. ELECTRIC OUTLET ON WEST WALL INOP. 5. EACH EXISTING BEDROOM AND HALL/ROOM LEADING TO BEDROOMS MUST HAVE AT LEAST BATTERY OPERATED SMOKE DETECTORS. 6. DOUBLE KET DEAD BOLTS NOT ALLOWED ON ALL EIXT DOORS. 7. LABLE ALL CIRCUITS IN ELECTRIC PANEL. 8. FILL ALL OPEN HOLES IN ELECTRIC PANEL. 9. HEAT PUMP INOP. 10. BIRD BOARDS REQUIRED S.W. CORNER. 11. ABS PLASTIC VENTS ON ROOF MUST HAVE LATEX PAINT. 12. CLEAN OUT MUST HAVE THREADED CAP AND TRIM TO GRADE. |