Inspection Status: Approved
Inspection History: ROOF NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/11/2001 |
ROOF NAILING |
|
Approved |
IVRS - Inspection 0000* |
| 12/26/2000 |
ROOF NAILING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/1. DOUBLE 2 X 4 POST CANNOT BE SPLICED. 2. UNTREATED WOOD CANNOT BE IN CONTACT WITH CONCRETE. 3. PLAN CALLS FOR 2 X 8 AT 16" O.C. SPACED AT 24" O.C. IN 6 FEET OF ADDN. 4. UNTREATED WOOD CANNOT BE WIHTIN 6" OF SOIL. 5. WIRES WITHIN 1 1/4 OF SURFACE. 6. ELECTRIC REQUIRES BUSHINGS AT METAL STUDY. 7. INADEQUATE NATURAL LITE. 300 SF HAS 20 SF NOW. 8. NO OTHER ELECT OUTLETS ALLOWED ON BATHROOM GFCI. 9. BATHROOM MUST BE 20 AMP TO GFC 12 GAUGE LINE. 10. ELECT CIRCUIT FOR HEAT PUMP. OK TO INSULATE AND DRYWALL ALL BUT BATH N. WALL AND MBR N. WALL/ELECT AND POST. |