Permit Details

Status:
C of o
Type:
COMMERCIAL OTHER
Apply Date:
08/14/2000
Applicant:
METRO PERMIT EXPRESS
Description:
TI:OFFICE
Architects:
  • GOLDSTEIN, GENE
Contractors:
  • GOLDSTEIN CONSTRUCTION MANAGEMEN

Permit Reviews

Permit Number - T00CM04027
Permit Status: C of o
Permit Description: TI:OFFICE
Start Date Submittal Complete Date Status  
01/08/2001 REVISION 01/17/2001 COMPLETED Review Details
01/17/2001 RESUBMITTAL 01/26/2001 COMPLETED Review Details
08/14/2000 COMMERCIAL TI 09/20/2000 COMPLETED Review Details
09/20/2000 COMMERCIAL TI 10/09/2000 COMPLETED Review Details
10/09/2000 REVISION 10/18/2000 COMPLETED Review Details
10/18/2000 RESUBMITTAL 10/19/2000 COMPLETED Review Details
11/15/2000 REVISION 11/20/2000 COMPLETED Review Details
12/06/2000 REVISION 12/06/2000 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T00CM04027
Permit Status: C of o
Permit Description: TI:OFFICE
Total Outstanding Activity Conditions - 1
Date Name
08/14/2000 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T00CM04027
Permit Description: TI:OFFICE
Total Completed Inspections - 12
Date Description Inspector Results Comments
10/23/2000 PLUMBING - PROGRESS RMYERS Approved IVRS - Inspection 0000*
ABS HORIZONTAL TO BE SUPPORTED EVERY 4" WITH APPROVED HANGERS
VENTS SHALL BE RUN LEVEL, OR 50 PITCH BACK TO FIXTURE, WITH NO DROOPS OR SAGS
10/23/2000 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection 0000*
DWV PIPING OK
COPPER PIPING OK
OK TO COVER WALLS
10/23/2000 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection 0000*
ABS UNDERGROUND OK
ABS WATER TEST OK
TRANSITION FITTINGS OK
CLEAN OUT EXTENSIONS SHALL BE MADE WITH WYE BRANCH FITTINGS
OK TO COVER
EXISTING PIPES CAPPED OFF OK
10/26/2000 FRAMING DWITT Approved IVRS - Inspection 0000*
11/03/2000 SHEET ROCK NAILING DWITT Approved IVRS - Inspection 0000*
APPROVED AS NOTED
RE-SCREW WHERE SCRW IS LESS THAN 3/8" FROM EDGE OR END
RE-SCREW WHERE PAPER IS BROKEN
11/23/2000 PLUMBING - GAS PRESSURE TEST RMYERS Approved IVRS - Inspection 0000*
BEFORE FINAL GAS INSPECTION PLEASE PROVIDE
REVISED APPROVED PLAN SHOWING EXTRA ROOF TOP UNIT AND NEW PIPING TO WATER HEATER WITH REVISED SIZING
AGA VALVE FOR WATER HEATER FLUE PIPING FOR WATER HEATER
12/12/2000 ELECTRIC - INTERMEDIATE JORTA Approved IVRS - Inspection 0000*
NEED PROPER SUPPORT FOR DISCONNECT SWITCHES AT ROOF
IMPROPER WAKING CLEARANCE IN FRONT OF DISCONNECTS
NEED MAINTANCE RECEPTACLES FOR ROOF TOP UNITS. WITHIN 25 FT OF.
LOW VOLTAGE THERMO WIRE IN SAME ENCLOSURE
12/13/2000 PLUMBING - FINAL RMYERS Approved IVRS - Inspection 0000*ALL CORRECTIONS MADE
OK FOR C OF O PENDING ANY OTHER INSPECTIONS AND VERIFICATION CERTIFICATION ON RPPBP
12/14/2000 ELECTRIC - FINAL JORTA Approved OK FOR TEMP C/O IVRS - Inspection 0000*
12/14/2000 ELECTRIC - ABOVE CEILING JORTA Approved IVRS - Inspection 0000*
OK FOR TEMPORARY CERTIFICATE OF OCCUPANCY ELECTRICAL LAST INSPECTOR SUBJECT TO BOND BEING POSTED
12/14/2000 BUILDING - FINAL DWITT Approved IVRS - Inspection 0000*
APPROVED AS NOTED
POST THE MAIN EXIT "THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS
03/21/2001 PERMIT FINALED DWITT Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CERT OF OCC VIEW