Permit: T00CM03058
Permit Details
Apply Date:
06/19/2000
Applicant:
HOLLAND INVESTMENTS ,
Description:
ADDITION:BEDROOM/STUDY/TWO BATHROOMS
Contractors:
- HOLLAND INVESTMENTS ,
Permit Reviews
Permit Number - T00CM03058
Permit Status: Final
Permit Description: ADDITION:BEDROOM/STUDY/TWO BATHROOMS
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/07/2000 | RESIDENTIAL BLDG/ZONING/FLOOD | 08/18/2000 | COMPLETED |
| 08/18/2000 | RESIDENTIAL BLDG/ZONING | 02/02/2001 | COMPLETED |
Completed Inspections
Permit Status: Final
Permit Number: T00CM03058
Permit Description: ADDITION:BEDROOM/STUDY/TWO BATHROOMS
Total Completed Inspections - 20
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/11/2001 | PLUMBING - SEWER HCS CONNECT | JRIVA | Approved | IVRS - Inspection 0000* |
| 01/11/2001 | PLUMBING - ROUGH, SOIL | JRIVA | Approved | IVRS - Inspection 0000* |
| 02/22/2001 | EXCAVATION/LAYOUT REBAR & ZON | JRIVA | Approved | IVRS - Inspection 0000* |
| 02/23/2001 | BUILDING PRE-SLAB | JRIVA | Approved | IVRS - Inspection 0000* |
| 03/27/2001 | ELECTRIC - SERVICE UPGRADE | JRIVA | Approved | IVRS - Inspection 0000* |
| 03/27/2001 | ELECTRIC - CABLE DROP | JRIVA | Approved | IVRS - Inspection 0000* |
| 04/18/2001 | EXT METAL CLIPS/EXT SHEATHING | JRIVA | Approved | IVRS - Inspection 0000* |
| 05/21/2001 | MECHANICAL - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection 0000* |
| 05/21/2001 | PLUMBING - GAS PRESSURE TEST | JRIVA | Approved | IVRS - Inspection 0000* |
| 05/21/2001 | PLUMBING - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection 0000* |
| 05/21/2001 | ELECTRIC - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection 0000* |
| 05/21/2001 | STUCCO MESH | JRIVA | Approved | IVRS - Inspection 0000* |
| 05/21/2001 | FRAMING | JRIVA | Approved | IVRS - Inspection 0000* |
| 05/21/2001 | ROOF NAILING | JRIVA | Approved | IVRS - Inspection 0000* |
| 06/08/2001 | SHEET ROCK NAILING | JRIVA | Approved | IVRS - Inspection 0000* |
| 11/01/2001 | MECHANICAL - FINAL | JRIVA | Approved | IVRS - Inspection 0999* |
| 11/01/2001 | PLUMBING - FINAL | JRIVA | Approved | IVRS - Inspection 0999* |
| 11/01/2001 | ELECTRIC - FINAL | JRIVA | Approved | IVRS - Inspection 0999* |
| 11/01/2001 | BUILDING - FINAL | JRIVA | Approved | IVRS - Inspection 0999*/ 1) ABS PLASTIC VENTS ON ROOF MUST BE PROTECTED WITH LATEX PAINT 2) HOUSE MUST HAVE 3017 ADDRESS IN MINIMUM 3" HIGH NUMERALS 3) LAUNDRY DRYER OUTLET MUST BE FOUR CONDUCTOR OUTLET 4) EACH VANITY MUST HAVE A 20 AMP GFCI OUTLET 5) CLOTHES CLOSET MUST HAVE SHIELDED LIGHT FIXTURES 6) LABEL ALL CIRCUITS IN PANEL 7) DOUBLE LUGGING OF NEUTRALS NOT ALLOWED |
| 01/08/2002 | PERMIT FINALED | JRIVA | Approved |