Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 01/08/2002 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 01/07/2002 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) NO ONE HOME. NO ACCESS TO PROJECT. RESCHEDULE |
| 11/01/2001 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) ABS PLASTIC VENTS ON ROOF MUST BE PROTECTED WITH LATEX PAINT 2) HOUSE MUST HAVE 3017 ADDRESS IN MINIMUM 3" HIGH NUMERALS 3) LAUNDRY DRYER OUTLET MUST BE FOUR CONDUCTOR OUTLET 4) EACH VANITY MUST HAVE A 20 AMP GFCI OUTLET 5) CLOTHES CLOSET MUST HAVE SHIELDED LIGHT FIXTURES 6) LABEL ALL CIRCUITS IN PANEL 7) DOUBLE LUGGING OF NEUTRALS NOT ALLOWED |