Permit Details

Status:
Expired
Type:
SINGLE FAMILY ALTERATION
Apply Date:
04/11/2000
Applicant:
MAHER, JOSEPH SAID JR
Description:
REMODEL:BEDROOM/FM ROOM/CARPORT INTO GARAGE
Architects:
  • MAHER, JOSEPH SAID JR
Contractors:
  • TAMARRON HOMES INC ,

Permit Reviews

Permit Number - T00CM01827
Permit Status: Expired
Permit Description: REMODEL:BEDROOM/FM ROOM/CARPORT INTO GARAGE
Start Date Submittal Complete Date Status  
08/17/2000 RESIDENTIAL BLDG/ZONING 08/17/2000 COMPLETED Review Details
10/03/2000 REVISION 01/31/2001 COMPLETED Review Details

Outstanding Inspections

Permit Status: Expired
Permit Number: T00CM01827
Permite Description: REMODEL:BEDROOM/FM ROOM/CARPORT INTO GARAGE
Total Outstanding Inspections - 7
Last Inspection Date Description Inspector Results Comments
05/30/2000 PLUMBING - ROUGH, SOIL N/A Partial Approval IVRS - Inspection 0000*
08/04/2000 MECHANICAL - INTERMEDIATE N/A Partial Approval
08/18/2000 SHEET ROCK NAILING N/A Partial Approval IVRS - Inspection 0000*/GARAGE AND HOME ALL BUT M/BR WEST WALL OK. NOTE: IF YOU ARE GOING TO DO STRUCTURAL CHANGES TO WEST WALL I WANT TO INSPECT PRIOR TO COVER.
12/05/2000 BUILDING - FINAL N/A Denied IVRS - Inspection 0999*/1. ROOF TOP FURNACE GAS LINES MUST BE PROPERLY SUPPORTED BY SHUT OFF VALVES. 2. ABS AND PVC PLUMBING MUST BE PROTECTED WITH LATEX PAINT. 3. DWV WASTE VENTS CANNOT BE DRILLED AND TAPPED FOR CONNECTION OF CONDENSATE DRAINS. INSTALL SANITARY TEES WITH PROPER REDUCERS. 4. OUTSIDE HOSE BIBS REQUIRE ANTI SIPHON VALVES. 5. BARE WIRES BACK PORCH 3 LOCATIONS. 6. WATER HEATER T AND P DRAIN MUST HAVE FULL BORE DRAIN VALVE PATCH CEILING.
12/05/2000 ELECTRIC - FINAL N/A Denied IVRS - Inspection 0999*
12/05/2000 PLUMBING - FINAL N/A Denied IVRS - Inspection 0999*
12/05/2000 MECHANICAL - FINAL N/A Denied IVRS - Inspection 0999*

Completed Inspections

Permit Status: Expired
Permit Number: T00CM01827
Permit Description: REMODEL:BEDROOM/FM ROOM/CARPORT INTO GARAGE
Total Completed Inspections - 2
Date Description Inspector Results Comments
09/15/2000 EXT METAL CLIPS/EXT SHEATHING MCAPISTR Approved IVRS - Inspection 0000*
09/22/2000 FRAMING JRIVA Approved IVRS - Inspection 0000*/DO NOT COVER ELECTRIC CABLES ON THE WEST PORCH. 2 EASCH NMC CANNOT PENETRATE. ADOBE UNPROTECTED USE UF CABLE PER ACT 339 N.E.C.

Documents

File Name Document Type  
None DOCUMENTS VIEW