Inspection Status: Denied
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 12/05/2000 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/1. ROOF TOP FURNACE GAS LINES MUST BE PROPERLY SUPPORTED BY SHUT OFF VALVES. 2. ABS AND PVC PLUMBING MUST BE PROTECTED WITH LATEX PAINT. 3. DWV WASTE VENTS CANNOT BE DRILLED AND TAPPED FOR CONNECTION OF CONDENSATE DRAINS. INSTALL SANITARY TEES WITH PROPER REDUCERS. 4. OUTSIDE HOSE BIBS REQUIRE ANTI SIPHON VALVES. 5. BARE WIRES BACK PORCH 3 LOCATIONS. 6. WATER HEATER T AND P DRAIN MUST HAVE FULL BORE DRAIN VALVE PATCH CEILING. |