Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 09/22/2000 |
FRAMING |
|
Approved |
IVRS - Inspection 0000*/DO NOT COVER ELECTRIC CABLES ON THE WEST PORCH. 2 EASCH NMC CANNOT PENETRATE. ADOBE UNPROTECTED USE UF CABLE PER ACT 339 N.E.C. |
| 07/28/2000 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/1. 2 OUTLETS ARE LIGHT AND 2WAY SW MISSING PANEL RAY. 2. 2 LIGHTS MISSING LAUNDRY..3. GROUND METAL SW BOX GUEST ROOM. 4. MAKE UP AND PROTECT WIRES BATHROOM. 5. NAIL PROTECT SHOWER VENT. 6. W/C REQUIRES RELOCATION. 7. N/SHOWER NOT READY. COMPLETE AND NAIL PROTECT. 8. F/BLOCK FURR OUT N/CLOSET. 9. M/BR AND BATH DUCT WERE NOT SIZED PER PLAN. REPAIR OR REVISE PLAN AND HAVE APPROVED. 10. L/R SOUTH WALL NOT READY. 11. NO GAS PRESSURE TEST REQ. 10 PSI MIN. |