Permit Details

Status:
Final
Type:
DUPLEX NEW
Address NEW:
500 N FORGEUS AV #100
Apply Date:
03/29/2000
Applicant:
N/A
Description:
DUP:TD#14-68-29
Contractors:
  • SIERRA PACIFIC BUILDING INC ,

Completed Inspections

Permit Status: Final
Permit Number: T00CM01588
Permit Description: DUP:TD#14-68-29
Total Completed Inspections - 22
Date Description Inspector Results Comments
04/03/2000 ELECTRIC - UFER KBOLLE Approved IVRS - Inspection 0999*
04/03/2000 ELECTRIC - UFER KBOLLE Approved ADDTL COMMS - ATTACH GROUND WIRE TO REBAR AT BOTTOM OF TRENCH
04/17/2000 PLUMBING - SEWER HCS CONNECT TRINIVJR Approved ADDTL COMMS - 1. WATER CLOSET BRANCH EXCEEDS 5-0 FROM MAIN TRUCK LINE. W.C. WILL REQUIRE FULL SIZE C.O. @ EACH UNIT 2. YARD WATER LINE OK 3. SEWER HCS CONNECTION OK 4. OK TO BACKFILL SITE SEWER AND WATER ONLY 5. RETEST ROUGH PLDG IN BLDG ONLY
04/17/2000 PLUMBING - YARD WTR LINE/TEST TRINIVJR Approved ADDTL COMMS - 1. WATER CLOSET BRANCH EXCEEDS 5-0 FROM MAIN TRUNK LINE W.C. WILL REQUIRE FULL SIZE C.O. @ EACH UNIT 2. YARD WATER LINE OK 3. SEWER HCS CONNECTION OK 4. OK TO BACKFILL SITE SEWER AND WATER ONLY 5. RETEST ROUGH PLDG IN BLDG ONLY
04/18/2000 PLUMBING - ROUGH, SOIL TRINIVJR Approved ADDTL COMMS - 1. NO CORRECTIONS HAVE BEEN MADE 2. OK TO BACKFILL TRENCH
10/02/2000 ROOF NAILING AMATHIES Approved IVRS - Inspection 0000*
10/02/2000 EXT METAL CLIPS/EXT SHEATHING AMATHIES Approved IVRS - Inspection 0000*
10/11/2000 PLUMBING - GAS PRESSURE TEST JSTANLEY Approved IVRS - Inspection 0000*
TEST ONLY PROVIDE FHA STRAPS MOVE HANGERS
10/12/2000 FRAMING EMONAHAN Approved IVRS - Inspection 0000*
10/13/2000 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection 0000*
10/16/2000 PLUMBING - INTERMEDIATE JSTANLEY Approved IVRS - Inspection 0000*
PLEASE INSTALL RELIEF LINE'S AND COMPLETE FHA STRAPS BANG PLATES
10/16/2000 ELECTRIC - INTERMEDIATE MCAPISTR Approved IVRS - Inspection 0000*
10/24/2000 SHEET ROCK NAILING DWITT Approved IVRS - Inspection 0000*
10/24/2000 STUCCO MESH DWITT Approved IVRS - Inspection 0000*
12/19/2000 ELECTRIC - CABLE DROP DSANTACR Approved IVRS - Inspection 0000*
OK CABLE DROP AND METER BUT NO POWER
GROUNDING ELECTRODE CONDUTOR MUST BE UNSPLICED OR SPLICED BY MEANS SPECIFIED BY N.E.C. 250-50
ALSO APPLY ANTI OXIDENT COMPOUND ON ALUMIIMUM FEEDER TO UNITS, BOTH ENDS
PRIOR TO NEXT INSPECTION HAVE PLANS, PERMITS ON SITE
01/05/2001 ELECTRIC - TEMPORARY SERVICE DSANTACR Approved
01/22/2001 PLUMBING - FINAL TRINIVJR Approved IVRS - Inspection 0000*
PLDG FINAL OK
OK FOR C OF O
NOTE: GAS CLEARANCE CARDS HAS BEEN ISSUED
01/25/2001 PERMIT FINALED EMONAHAN Approved
01/25/2001 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection 0000*
01/25/2001 BUILDING - FINAL EMONAHAN Approved IVRS - Inspection 0000*
01/25/2001 U VALUE FOR WINDOW EMONAHAN Approved
01/31/2001 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection 0000*