Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T00CM00915
Permit Details
Apply Date:
02/25/2000
Applicant:
METRO PERMIT EXPRESS
Description:
TI:OFFICE
Architects:
- MCCARTHY, BRIAN PATRICK
Contractors:
- CHESTNUT CONSTRUCTION CORPORATIO
Completed Inspections
Permit Status: C of o
Permit Number: T00CM00915
Permit Description: TI:OFFICE
Total Completed Inspections - 4
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/20/2000 | ELECTRIC - INTERMEDIATE | KBOLLE | Approved | ADDTL COMMS - WALLS OK |
04/10/2000 | PLUMBING - INTERMEDIATE | TRINIVJR | Approved | ADDTL COMMS - 1.WASTE AND VENT SYSTEM OK 2. OVERHEAD WATER DISTRIBUTION OK 3. WILL REQUIRE A C.O. WHERE DWV WASTE LINE FOR RM#135,130 EXCEEDS 135 DEGREES 4. MUST REVERSE OR REMOVE TEST WYES NO FITTING MAY BE INSTALLED WITH REVERSE FLOW 5. FLAT VENT FOR BACK TO BACK W.C. IS REVERSED. REMOVE SAN TEE AND REPLACE WITH DRAINAGE FITTING. 6. CAN NOT WET VENT DRINKING FOUNTAIN BETWEEN FLOORS 7. OK TO DRYWALL. |
06/02/2000 | ELECTRIC - FINAL | DSANTACR | Approved | |
06/02/2000 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved |