Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Development Package
Address NEW:
6207 E BELLEVUE ST
Apply Date:
12/30/2021
Applicant:
Description:
Site/Grading - Rook Bellevue Homes. Multi-family with single family units.

Permit Reviews

Permit Number - DP21-0361
Permit Status: Inspections
Permit Description: Site/Grading - Rook Bellevue Homes. Multi-family with single family units.
Start Date Submittal Complete Date Status  
01/11/2022 DEV PKG 02/28/2022 COMPLETED Review Details
07/08/2022 DEV PKG - RESUBMITTAL 08/31/2022 COMPLETED Review Details
12/30/2021 DEV PKG - OK TO SUBMIT 01/11/2022 COMPLETED Review Details
12/22/2022 DEVELOPMENT PACKAGE REVIEW v.2 01/13/2023 APPROVED Review Details
11/18/2022 DEVELOPMENT PACKAGE REVIEW v.1 12/13/2022 REQUIRES RESUBMIT Review Details

Conditions

Permit Number - DP21-0361
Permit Status: Inspections
Permit Description: Site/Grading - Rook Bellevue Homes. Multi-family with single family units.
Date Description Comments
01/06/2023 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit.
01/06/2023 Dust Control/Air Quality Permit is Required.

Outstanding Inspections

Permit Status: Inspections
Permit Number: DP21-0361
Permite Description: Site/Grading - Rook Bellevue Homes. Multi-family with single family units.
Total Outstanding Inspections - 5
Last Inspection Date Description Inspector Results Comments
11/13/2023 ENGR Grading Final N/A Not Ready soil stockpiles need stormwater protection (second notice)
06/26/2024 COT - ENGR - Stormwater N/A Complete (Recurring) No concerns at this time stormwater
07/24/2024 PDSD Site/Engineering Division - NPPO N/A Partial Pass Contractor called in the wrong inspection contractor get the footers and the rebar layout for the trash enclosure
08/01/2024 PDSD Site/Engineering Division - Landscaping N/A Not Ready I met with a contractor on the site to take a look and see what is happening at this time. The trash enclosure footers have been poured, and the bollards have been set in place place. the contractor will be working on constructing the walls for the trash enclosure. I have advised the contractor that when they are constructing the walls, they have to stop at 4 foot and grout all cells prior to going any higher above the 4 foot level. He will take pictures of the wall once they have it to 4 foot will have the grout placed and will take pictures of the grout prior to installing the additional 2 foot on top of the lower wall. Once he is done with the upper wall, then they will grout that and ensuring that a bond beam is at the top of the wall and will provide photos of the completed work.
There have been questions asked about the permits for the houses that are requiring a special inspection for grade. I have advised him to contact Joshua Garcia or Stephen blood to make a determination if a special inspection is required. for any of the work as noted on the Approved plans. I also have advised him to talk to Joshua Garcia about what Permits will be required for the the retaining walls and screen walls shown on his building plans.
08/15/2024 ENGR - Drainage Structures N/A Partial Pass Contractor warming up the apron and the floor for the trash enclosure and set the steel per plan. Everything looks good. Good to poor.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
DP21-0361-ROOK-BELLEVUE DP_V1.PDF DOCUMENTS VIEW
SUB3_ROOK-BELLEVUE HOMES DRAINAGE REPORT_V1.PDF DOCUMENTS VIEW
2_121-08-047A, PIMA CO ASSESSORS LETTER, CONSOLIDATION.PDF PLANS UNDER REVIEW VIEW
2_1ST SUBMITTAL, COMMENT-RESPONSE LETTER.PDF PLANS UNDER REVIEW VIEW
2_ONLINE SUBMITTAL PAGE, RECVD 06.30.22.PDF PLANS UNDER REVIEW VIEW
2_LANDSCAPRE COMMENT REPONSE LETTER.PDF PLANS UNDER REVIEW VIEW
2_DP21-0361-ROOK-BELLEVUE DP, DEVELOPMENT PACKAGE.PDF PLANS UNDER REVIEW VIEW
2_PC ADDRESSING REDLINE RESPONSES.PDF PLANS UNDER REVIEW VIEW
2_ROOK-BELLEVUE HOMES DRAINAGE REPORT.PDF PLANS UNDER REVIEW VIEW
PIMA CO ADDRESSING REVIEW COMMENTS, FIRST SUBMITTAL, 02.14.22.PDF DOCUMENTS VIEW
1_21002229-ROOK-BELLEVUE DP.PDF PLANS UNDER REVIEW VIEW
1_ONLINE SUBMITTAL APPLICATION, RECVD 12.28.21.PDF PLANS UNDER REVIEW VIEW
1_ROOK-BELLEVUE HOMES DRAINAGE REPORT.PDF PLANS UNDER REVIEW VIEW
1_PRESUBMITTAL RESPONSE LETTER, T21PRE0167, AUGUST 2021.PDF PLANS UNDER REVIEW VIEW
1_ROOK-BELLEVUE SEWER DESIGN REPORT.PDF PLANS UNDER REVIEW VIEW
1-DEV PKG APPLICATION.PDF PLANS UNDER REVIEW VIEW