Permit Details

Status:
Complete
Type:
Development Package
Apply Date:
10/30/2020
Applicant:
Jean Armstrong
Description:
Site/Grading/SWPPP - Tucson Medical Center, Rincon ASC, new medical office.

Permit Reviews

Permit Number - DP20-0226
Permit Status: Complete
Permit Description: Site/Grading/SWPPP - Tucson Medical Center, Rincon ASC, new medical office.
Start Date Submittal Complete Date Status  
02/01/2021 DEV PKG - RESUBMITTAL 03/15/2021 COMPLETED Review Details
03/15/2021 DEV PKG - RESUBMITTAL 03/19/2021 COMPLETED Review Details
10/30/2020 DEV PKG - OK TO SUBMIT 11/04/2020 COMPLETED Review Details
11/04/2020 DEV PKG 01/18/2021 COMPLETED Review Details

Completed Inspections

Permit Status: Complete
Permit Number: DP20-0226
Permit Description: Site/Grading/SWPPP - Tucson Medical Center, Rincon ASC, new medical office.
Total Completed Inspections - 9
Date Description Inspector Results Comments
08/02/2022 PDSD Site/Engineering Division - Landscaping Passed {Activity date: 08/02/2022; Status: Approved; Inspector: DROBERTS; Comment: Entered by DROBERT5 - }
08/02/2022 PDSD Site/Engineering Division - NPPO Passed {Activity date: 08/02/2022; Status: Approved; Inspector: DROBERTS; Comment: Entered by DROBERT5 - } ; {Activity date: 05/11/2022; Status: Continued; Inspector: MHERNANDEZ; Comment: Entered by VVERA1 - CN STILL NEED TO FINISH THE PLANTING.}
08/02/2022 ENGR Engineering Final Passed {Activity date: 08/02/2022; Status: Approved; Inspector: DROBERTS; Comment: Entered by DROBERT5 - } ; {Activity date: 04/29/2022; Status: Not ready for Inspection; Inspector: DROBERTS; Comment: Entered by VVERA1 - IS NOT READY AT THIS TIME, LANDSCAPE CREWS WORKING ON IRRIGATION LINE INSTALLATIONS. THE FOLLOWING AREAS WERE NOTED AS NEEDING ATTENTION: 1) ADVISED THE CONTRACTOR THAT THE ADA PARKING SPACES AND ACCESS AISLES WERE NON-COMPLIANT FOR GRADES, AREAS EXCEEDING 2% WITHIN THE DESIGNATED SPACES. 2) THE SIDEWALK RAMPS LOCATED ALONG THE SOUTH SIDE OF THE BUILDING EXCEED 5% IN THE RUNNING SLOPE AND WILL REQUIRE HANDRAILS ON BOTH SIDES OF THE AFFECTED SIDEWALKS/RAMPS(3). 3) ALL CRACKS IN THE SIDEWALKS FOR THIS SITE WILL BE CHECKED TO ENSURE THST THEY HAVE BEEN REPLACED AS REQUIRED. I HAVE ADVISED THE CONTRACTOR THAT EVERY CRACK WILL BE CHECKED FOR MOVEMENT. ALSO ANY PANEL WITH MORE THAN ONE CRACK IN IT WILL NEED TO BE REMOVED AND REPLACED. 4) ADJACENT TO THE TRASH ENCLOSURE THE CONTRACTOR ADDED AN ADDITIONAL WATER HARVESTING BASIN. I HAVE ASKED FO THIS TO BE PUT ON THE APPROVED PLANS AS A REVISION PRIOR TO CLOSING THIS PROJECT OUT. THIS SITE WILL BE RE-INSPECTED PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY.} ; {Activity date: 04/07/2022; Status: Continued; Inspector: MHERNANDEZ; Comment: Entered by NGARCIA3 - CN CONTRACTOR NOT ON SITE NEED TO RESCHEDULE.}
08/02/2022 SITE - Stormwater Follow-up Passed {Activity date: 08/02/2022; Status: Approved; Inspector: DROBERTS; Comment: Entered by DROBERT5 - } ; {Activity date: 03/10/2022; Status: Continued; Inspector: MHERNANDEZ; Comment: Entered by NGARCIA3 - CN/ NO CONCERNS AS OF TODAY} ; {Activity date: 02/15/2022; Status: Continued; Inspector: MHERNANDEZ; Comment: Entered by VVERA1 - CN/ GOOD} ; {Activity date: 01/28/2022; Status: Continued; Inspector: DROBERTS; Comment: Entered by VVERA1 - IS CONTINUED, NO CONCERNS AT THIS TIME. ROADWAYS AND PARKING AROUND THE NEW BUILDING HAS NOT BEEN CONSTRUCTED AT THIS TIME

} ; {Activity date: 01/19/2022; Status: Continued; Inspector: MHERNANDEZ; Comment: Entered by NGARCIA3 - CN /GOOD AT IS TIME NO CHANGE.} ; {Activity date: 01/04/2022; Status: Continued; Inspector: MHERNANDEZ; Comment: Entered by RSALDAT1 - CN /EVERYTHING LOOKS GOOD AT IS TIME.} ; {Activity date: 12/08/2021; Status: Continued; Inspector: MHERNANDEZ; Comment: Entered by VVERA1 - CN/GOOD AT IS TIME} ; {Activity date: 12/02/2021; Status: Continued; Inspector: MHERNANDEZ; Comment: Entered by VVERA1 - CN GOOD AT IS TIME.} ; {Activity date: 11/10/2021; Status: Continued; Inspector: MHERNANDEZ; Comment: Entered by VVERA1 - CN GOOD AS OF TODAY.} ; {Activity date: 10/14/2021; Status: Continued; Inspector: MHERNANDEZ; Comment: Entered by NGARCIA3 - CN / GOOD AT IS TIME} ; {Activity date: 09/28/2021; Status: Continued; Inspector: MHERNANDEZ; Comment: Entered by VVERA1 - CN /GOOD AT IS TIME /INFORMED THE CONTRACTOR TO CAAL IN FOR INSPECTION EVERY TWO WEEKS.

} ; {Activity date: 07/02/2021; Status: Continued; Inspector: DROBERTS; Comment: Entered by RSALDAT1 - CONTINUED, NO CONCERNS AT THIS TIME
} ; {Activity date: 06/18/2021; Status: Continued; Inspector: DROBERTS; Comment: Entered by DROBERT5 - NO CONCERNS AT THIS TIME} ; {Activity date: 06/10/2021; Status: Continued; Inspector: MHERNANDEZ; Comment: Entered by VLEON1 - } ; {Activity date: 05/28/2021; Status: Continued; Inspector: DROBERTS; Comment: Entered by VLEON1 - CN FOR 10360 E DREXEL RD - NO CONCERNS AT THIS TIME, STORMWATER CONTROLS APPEAR TO BE WORKING AS NEEDED.

REMEMBER TO MONITOR ALL OPEN SITES AT ALL TIMES TO ENSURE THAT BLOWING DUST IS KEPT TO A BARE MINIMUM, BLOWING DUST IS A CITABLE OFFENSE OFFENSE BY THE ARIZONA DEPARTMENT OF ENVIRONMENTAL QUALITY AND MAY ALSO CAUSE A SHUTDOWN OF A SITE.} ; {Activity date: 05/17/2021; Status: Continued; Inspector: MHERNANDEZ; Comment: Entered by VLEON1 - CN . NEED SOME WATTLES IN THE SOUTHEAST CORNER. OF PROJECT.

} ; {Activity date: 05/07/2021; Status: Continued; Inspector: DROBERTS; Comment: Entered by VLEON1 - CONTINUED, NO CONCERNS AT THIS TIME}
08/02/2022 ENGR Grading Final Passed {Activity date: 08/02/2022; Status: Approved; Inspector: DROBERTS; Comment: Entered by DROBERT5 - }
08/02/2022 SITE - Stormwater Final Inspection Passed {Activity date: 08/02/2022; Status: Approved; Inspector: DROBERTS; Comment: Entered by DROBERT5 - }
08/02/2022 SITE - Stormwater Setup and Controls Passed {Activity date: 08/02/2022; Status: Approved; Inspector: DROBERTS; Comment: Entered by DROBERT5 - } ; {Activity date: 01/11/2022; Status: Continued; Inspector: MHERNANDEZ; Comment: Entered by RSALDAT1 - CN/ EVERYTHING IS GOOD TODAY NO CONCERNS TODAY.}
08/02/2022 PDSD Engineering Division Pre-Construction SITE Passed {Activity date: 08/02/2022; Status: Approved; Inspector: DROBERTS; Comment: Entered by DROBERT5 - } ; {Activity date: 05/06/2021; Status: Partial Approval; Inspector: DROBERTS; Comment: Entered by VLEON1 - PARTIAL A THIS TIME. TMC WANTS TO HAVE A GROUNDBREAKING CEREMONY ON TUESDAY EVENING THIS WEEK. I HAVE ADVISED THE CONTRACTOR THAT THE CLEARING OF THIS PORTION OF THE SITE NEEDS TO BE MONITORED BY THE LANDSCAPE ARCHITECT FOR ALL REMOVALS. I HAVE VIEWED THE PLANS FOR THIS SITE AND THE NPPO IS VERY QUESTIONABLE AT THIS TIME. THE PLANS HAVE SHOWN THE SAVING OF 4 SAGUAROS BUT HAS NO CALL OUT LIST OF ANY OTHER PLANTS. THE LANDSCAPE PLANS FOR THIS SITE SHOWS NOT ONLY THE SAGUAROS ARE TO BE SAVED, BUT ALSO TREES AND BARREL CACTUS.}
08/02/2022 COT - ENGR - Signage Final Passed {Activity date: 08/02/2022; Status: Approved; Inspector: DROBERTS; Comment: Entered by DROBERT5 - } ; {Activity date: 04/07/2022; Status: Continued; Inspector: MHERNANDEZ; Comment: Entered by NGARCIA3 - CN NEED TO RESCHEDULE}

Documents

File Name Document Type  
MEMORANDUM OF GROUND LEASE, RECORDED ON 04.08.21.PDF DOCUMENTS VIEW
1-13 OF 13.PDF DEVELOPMENT PACKAGE VIEW
PERMIT DOCUMENTS VIEW
DEQ_FUGITIVEDUSTPERMIT.PDF DOCUMENTS VIEW
CONTRACTOR LETTER, KRAUS ANDERSON.PDF DOCUMENTS VIEW
PLAN FOR PLUMBING.PDF DOCUMENTS VIEW
PARKING AGREEMENT.PDF DOCUMENTS VIEW
TRANSMITTAL SHEET.PDF DOCUMENTS VIEW
TEP FACILITIES MAP, 11.13.20.PDF DOCUMENTS VIEW
APPLICATION DOCUMENTS VIEW
ENGINEER TRANSMITTAL COVER SHEET.PDF DOCUMENTS VIEW
HYDRO REPORT, STORMWATER MGMT.PDF DOCUMENTS VIEW
NPP EXCEPTION APPLICATION.PDF DOCUMENTS VIEW
REZONING-MINUTES 4-26-05.PDF DOCUMENTS VIEW
REZONING-ORDINANCE 10147, 4-26-05.PDF DOCUMENTS VIEW
SOILS REPORT, GEOTECHNICAL.PDF DOCUMENTS VIEW
SWPPP, 337 PAGES.PDF DOCUMENTS VIEW