Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Parcel Search
 
Parcel Attributes
Parcel12904007A
JurisdictionTucson, Pima County
City of Tucson ZoningR-2
Tucson WardWard 6
Flood Related InformationFEMA Floodplain Area
Tucson Registered NeighborhoodSam Hughes
Major Street & Route

Gateway Route

National Register Historic DistrictSam Hughes Residential Historic District
Structure on National Register of Historic Places

Contributor

Pima County Data Assessor, Recorder, Treasurer, ...
Parcel Map Map
Addresses
Parcel Attributes Issue?

Annexations & Original City Zoning (OCZ)

Date - 08/17/2026 11:33 a.m.
Total Number Of OZC Plans - (2)
Plan Description Annexation Ordinance Effective Date OCZ Ordinance
Fairmount And Alta Vista 539 04/04/1923
Part Of American Villa 597 06/02/1926

Permits

Parcel Number - 12904007A
Date - 08/17/2026 11:33 a.m.
Total Number Of Permits - (7)
Permit Permit Status Entered Date Expired Date Unit Type Description
TR-ROW-0125-00075 Complete 01/15/2025 05/10/2025 Right-of-Way (ROW) 324040 Urgent Sewer Repair located on north bound Campbell Ave. at E. 8th St. - Rehab bench to allow cctv camera access to the reach, clean line from MH 9907-12 to CO 9907*09 in order to repair the void in the 6" line near manhole 9907-12.
TR-ROW-0525-00672 Complete 05/16/2025 08/30/2025 Right-of-Way (ROW) 324040 Site 1 - Do to blockage in the sewer line PCRWRD has requested EMC repair the 6" sewer line from CO 9907*09 to MH 9907-12 by removing CO 9907*09 and replacing it with a terminal manhole and then removing all the debris from the 6" sewer line and install 242LF of 6" CIPP. EMC will also replace the concrete collar and do a bench rehab on MH 9907-12.
TE-FPU-0525-00217 Issued 05/28/2025 08/30/2025 Floodplain Use 324040 Site 1 - Do to blockage in the sewer line PCRWRD has requested EMC repair the 6" sewer line from CO 9907*09 to MH 9907-12 by removing CO 9907*09 and replacing it with a terminal manhole and then removing all the debris from the 6" sewer line and install 242LF of 6" CIPP. EMC will also replace the concrete collar and do a bench rehab on MH 9907-12.
T05AN00164 Issued 02/16/2005 N/A ADDRNEW
T05EL00339 Final 02/16/2005 08/17/2005 ELECT UPGRADE: SERVICE 125 AMP APA
T09PL01262 Final 07/29/2009 01/31/2010 PLUMB RE-ROUTE GAS LINE
T17RW01907 Final 05/04/2017 09/12/2017 ROW START POINT ON THE EAST SIDE OF CAMPBELL AND S OF 8TH ST BEGIN OVERLASH OF 24CT FIBER 1207' TO TEP POLE CROSSING E BROADWAY CONTINUE 717' OVERLASH TO TEP POLE 333

Code Enforcement

Parcel Number - 12904007A
Date - 08/17/2026 11:33 a.m.
Total Number Of Code Cases - 2
Case Number Case Status Entered Date Closed Date Unit Type Description
T11DV05392 Noverify 07/15/2011 N/A DNR_VIOL Weeds and trash on site.
T11DV05523 Noverify 07/20/2011 N/A DNR_VIOL Overgrown weeds and trash on site.