Permit: TR-ROW-0525-00672
Permit Details
Apply Date:
05/16/2025
Applicant:
Description:
324040 Site 1 - Do to blockage in the sewer line PCRWRD has requested EMC repair the 6" sewer line from CO 9907*09 to MH 9907-12 by removing CO 9907*09 and replacing it with a terminal manhole and then removing all the debris from the 6" sewer line and install 242LF of 6" CIPP. EMC will also replace the concrete collar and do a bench rehab on MH 9907-12.
Permit Reviews
Permit Number - TR-ROW-0525-00672
Permit Status: Complete
Permit Description: 324040 Site 1 - Do to blockage in the sewer line PCRWRD has requested EMC repair the 6" sewer line from CO 9907*09 to MH 9907-12 by removing CO 9907*09 and replacing it with a terminal manhole and then removing all the debris from the 6" sewer line and install 242LF of 6" CIPP. EMC will also replace the concrete collar and do a bench rehab on MH 9907-12.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/16/2025 | RIGHT-OF-WAY REVIEW v.1 | 05/20/2025 | REQUIRES RESUBMIT |
| 05/28/2025 | RIGHT-OF-WAY REVIEW v.2 | 05/28/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TR-ROW-0525-00672
Permit Status: Complete
Permit Description: 324040 Site 1 - Do to blockage in the sewer line PCRWRD has requested EMC repair the 6" sewer line from CO 9907*09 to MH 9907-12 by removing CO 9907*09 and replacing it with a terminal manhole and then removing all the debris from the 6" sewer line and install 242LF of 6" CIPP. EMC will also replace the concrete collar and do a bench rehab on MH 9907-12.
Total Outstanding Activity Conditions - 6
| Date | Name |
|---|---|
| 05/19/2025 | BUS STOP/ ROUTE |
| 05/19/2025 | PRE-CON/PAVEMENT/SIDEWALK |
| 05/19/2025 | Traffic control set-up approved between 9AM - 3:30PM |
| 05/20/2025 | Message Boards to be Placed 5 days in advance of work, for public notification.. |
| 05/20/2025 | PAVEMENT PATCH TYPE SHALL BE IN CONFORMANCE TO THE CURRENT EDITION OF THE CITY OF TUCSON PUBLIC UTILITY ADMINISTRATIVE MANUAL. |
| 05/20/2025 | Pedestrian Access & Sidewalk PEDESTRIAN ACCESS MUST BE PROVIDED AND MAINTIANED PER MUTCD CHAPTER 6D. FIELD ADJUSTMENTS MAY BE REQUIRED. REPLACE/REPAIR SIDEWALK PANELS PER PAG STANDARD DETAIL 200\206 . SIDEWALK CLOSED AHEAD SIGNS SHALL BE PLACED AT THE NEAREST ADA ACCESS RAMPS IF LOCATED WITHIN 660' OF CLOSURE. PEDESTRIAN DETOUR ROUTE ON SAME SIDE OF RIGHT OF WAY TO BE PROVIDED IF NO ADA RAMPS ACCESSABLE. Refer to MUTCD Chapter 6 Figure 6P-28, and 6K figure 6K-2. |
Completed Inspections
Permit Status: Complete
Permit Number: TR-ROW-0525-00672
Permit Description: 324040 Site 1 - Do to blockage in the sewer line PCRWRD has requested EMC repair the 6" sewer line from CO 9907*09 to MH 9907-12 by removing CO 9907*09 and replacing it with a terminal manhole and then removing all the debris from the 6" sewer line and install 242LF of 6" CIPP. EMC will also replace the concrete collar and do a bench rehab on MH 9907-12.
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/28/2025 | TRSP - ROW - Pre-Activity Field/Pre-Construction Meeting | Passed | ||
| 08/28/2025 | TRSP - ROW - Backfill - Placement/Compaction | Passed | ||
| 08/28/2025 | TRSP - ROW - Final | Passed |