Parcel Number - 125011750
Date - 10/13/2026 2:28 a.m.
Total Number Of Permits - (3)
| Permit | Permit Status | Entered Date | Expired Date | Unit | Type | Description |
|---|---|---|---|---|---|---|
| TC-RES-0826-04493 | Issued | 08/12/2026 | 08/27/2027 | UNIT 47 | Residential Building - One or Two Family | - Reconfigure existing kitchen branch-circuit wiring for new kitchen layout. - Install and/or relocate kitchen receptacles as needed. - Provide required AFCI and GFCI protection for new and modified circuits. - Install new under-cabinet LED lighting, driver, associated wiring, and dimmer control. - Convert existing exterior 240V receptacle circuit to 120V and install new appropriately rated breaker and receptacle. - Install new bathroom recessed LED lighting as shown. - Install new and relocated bathroom receptacles and switches as shown. - Install one additional GFCI-protected receptacle at master bathroom vanity. - Install one wet-location-listed recessed LED fixture above master shower with new dedicated wall switch. - Remove two existing master bedroom nook receptacles and install new wiring and boxes for two wall sconces connected to existing switching. - Existing service and main electrical panel to remain. |
| TC-RES-0926-05145 | Withdrawn | 09/15/2026 | N/A | UNIT 47 | Residential Building - One or Two Family | Kitchen Remodel |
| TC-RES-1026-05537 | In review | 10/05/2026 | N/A | UNIT 47 | Residential Building - One or Two Family | - Interior kitchen plumbing alteration at 3022 E 6th Street, Unit 47, a second-floor dwelling unit. - Relocate one existing kitchen sink from the south wall to the west wall at the former stove location. Relocate the dishwasher beside the new sink, nearest the doorway. - Extend existing kitchen hot and cold water connections approximately 12 feet using new 1/2-inch PEX-A piping. Existing hot water is supplied by a shared community boiler. - Install new 1-1/2-inch ABS kitchen drain piping connected to the existing kitchen drain. Modify the existing vent connection while maintaining downstairs vent continuity. - Provide an accessible cleanout, listed air admittance valve under the sink cabinet, and dishwasher water and drain connections. - New cabinets and drywall work are by others and excluded from Tucson Plumbing Solutions scope. No wall relocation or reframing is proposed. - Electrical work is covered under separate permit TC-RES-0826-04493. - Previous Express application TC-RES-0926-05145 was requested to be withdrawn following the reviewer’s instruction to apply as Residential Addition/Alteration. |