Parcel Search: 121080360
Parcel Search
Parcel Attributes
| Parcel | 121080360 |
|---|---|
| Jurisdiction | Tucson, Pima County |
| City of Tucson Zoning | R-3 |
| Tucson Ward | Ward 6 |
| Pima County Data | Assessor, Recorder, Treasurer, ... |
| Parcel Map | Map |
| Parcel Attributes Issue? | |
Annexations & Original City Zoning (OCZ)
Date - 08/06/2026 5:34 a.m.
Total Number Of OZC Plans - (1)
Permits
Parcel Number - 121080360
Date - 08/06/2026 5:34 a.m.
Total Number Of Permits - (16)
| Permit | Permit Status | Entered Date | Expired Date | Unit | Type | Description |
|---|---|---|---|---|---|---|
| T02BU02255 | Final | 08/15/2002 | 04/29/2003 | #101 | BUILD | REPAIR:BALCONY BEAM |
| T02BU02256 | Final | 08/15/2002 | 04/29/2003 | #106 | BUILD | REPAIR:BEAM TO BALCONY |
| T02BU02257 | Final | 08/15/2002 | 04/29/2003 | #108 | BUILD | REPAIR:BALCONY BEAM |
| T02BU02258 | Final | 08/15/2002 | 04/29/2003 | #111 | BUILD | REPAIR:BALCONY BEAM |
| T02BU02259 | Final | 08/15/2002 | 04/29/2003 | #129 | BUILD | REPAIR:BALCONY BEAM |
| T02OT01266 | Final | 08/16/2002 | N/A | FLOODPLN | FLOODPLAIN USE PERMIT | |
| T04ME00687 | Expired | 10/21/2004 | 04/20/2005 | #106 | MECH | REPLACE: A/C (APA) |
| T06OT00497 | Withdrwn | 02/21/2006 | N/A | C-OF-O | C OF O : Manager's Office/Rec Room BLDG "G" " | |
| T06OT00498 | Withdrwn | 02/21/2006 | N/A | #101 | C-OF-O | C OF O Apartments #101 "A" |
| T06OT00499 | Withdrwn | 02/21/2006 | N/A | #108 | C-OF-O | C OF O APARTMENTS #108 "B" |
| T06OT00500 | Withdrwn | 02/21/2006 | N/A | #215 | C-OF-O | C OF O APARTMENTS #215 "C" |
| T06OT00501 | Withdrwn | 02/21/2006 | N/A | #222 | C-OF-O | C OF O APARTMENTS #222 "F" |
| T06OT00502 | Withdrwn | 02/21/2006 | N/A | #129 | C-OF-O | C OF O APARTMENTS #129 "E" |
| T06OT00503 | Withdrwn | 02/21/2006 | N/A | #136 | C-OF-O | C OF O Apartments #136 |
| T06OT01718 | Final | 06/28/2006 | 01/28/2007 | SIGN | 11422 | |
| T14CM00759 | Final | 02/07/2014 | 08/17/2014 | #240 | COMBO | RECONNECT: ELECTRIC |
Code Enforcement
Parcel Number - 121080360
Date - 08/06/2026 5:34 a.m.
Total Number Of Code Cases - 7
| Case Number | Case Status | Entered Date | Closed Date | Unit | Type | Description |
|---|---|---|---|---|---|---|
| T03DV01255 | Invalid | 12/29/2003 | N/A | #114 | DNR_VIOL | COMPLAINT:MIN HOUSING-ROACHES, DOOR NEEDS WEATHERIZATION. OTHER VARIOUS MIN HOUSING ISSUES. UNIT A206 DOOR FRAME CRACKED, CEILING DAMAGE |
| T04DV00493 | Complian | 06/09/2004 | N/A | #108 | DNR_VIOL | COMPLAINT:MIN HOUSING-#206 ROACHES, BALCONY BOARDS ROTTEN. #108 ROACHES, LEAKY FAUCETS, WATER PRESSURE NO GOOD, WATER LEAKS BEHIND WALLS. #206 CALLED BACK ON 08/04/04 - SUPPORT BEAM FOR BALCONY IS SPLIT, 1/2 CAN BE PULLED OUT. |
| T04VL00112 | Complian | 03/05/2004 | N/A | CODEVIOL | COMPLAINT:ILLEGAL SIGN | |
| T06FR00207 | Complete | 02/17/2006 | N/A | FIREINSP | Full inspection done 2/15/06 | |
| T07DV00382 | Noverify | 01/11/2007 | N/A | DNR_VIOL | ILLEGAL DUMPING BY TENANTS AT THIS ADDRESS AS WELL AS 6171 & 6151 E BELLEVUE//NEEDS RESOLUTION | |
| T10DV07071 | Noverify | 10/12/2010 | N/A | #136 | DNR_VIOL | Front door not installed correctly. Split door jambs. Wrought iron screen door not installed correctly and falling off. Porch roof and rafters/beams are split and coming apart.carcks in porch walls running length of corner, ceiling to floor.crack in outside wall in stucco. Interior wall has bolts pushing thru dry wall. Steps to upstairs apartments have large cracks. Interior dry wall has water damage /dry wall bowing in places. Secruity door has damage frame door does not close and latch properly.inside door handle is against door jamb making it hard to grasp door handle to open the door. Rafters/beams have water damage and are pulling loose from hanger strap. |
| T14DV00481 | Complian | 01/28/2014 | N/A | DNR_VIOL | ELECTRICAL HAZARDS IN COMMERCIAL BUILDING |