Parcel Search: 12008625A
Parcel Search
Parcel Attributes
| Parcel | 12008625A |
|---|---|
| Jurisdiction | Tucson, Pima County |
| Water Course | Street+culvert |
| City of Tucson Zoning | C-2 |
| Tucson Ward | Ward 1 |
| Tucson Registered Neighborhood | National City Northwest |
| Major Street & Route | Arterial or Collector |
| Pima County Data | Assessor, Recorder, Treasurer, ... |
| Parcel Map | Map |
| Address | |
| Parcel Attributes Issue? | |
Annexations & Original City Zoning (OCZ)
Date - 08/18/2026 10:29 a.m.
Total Number Of OZC Plans - (1)
Permits
Parcel Number - 12008625A
Date - 08/18/2026 10:29 a.m.
Total Number Of Permits - (8)
| Permit | Permit Status | Entered Date | Expired Date | Unit | Type | Description |
|---|---|---|---|---|---|---|
| TR-UTL-0223-00949 | Complete | 02/23/2023 | 05/23/2023 | Right-of-Way (ROW) - Utility | EXCAVATE (1) 5'X5' BELL HOLE IN CONCRETE SIDEWALK AND (1) 5'X5' BELL HOLE IN ASPHALT ON W IRVINGTON ST FOR GAS SERVICE REPLACEMENT. | |
| C10-01-55 | Approved | 06/16/2009 | N/A | Zoning Verification Letter | C10-01-55 Irvington Road - Seventh Avenue Apts. / Frank Cortes - - No | |
| TR-UTL-1025-01858 | Complete | 10/27/2025 | 11/30/2025 | Right-of-Way (ROW) - Utility | Repair broken fire hydrant. 24 hour closure | |
| T00CM00257 | Withdrwn | 01/20/2000 | N/A | COMBO | ADDITION: OFFICE & PORCH T99VL01722 | |
| T00CM05287 | Expired | 10/26/2000 | 06/10/2002 | COMBO | ADDITION:OFFICE, BATHROOM , FRONT PORCH | |
| T01PL01152 | Final | 06/05/2001 | 12/04/2001 | PLUMB | REPLACE:GAS LINE (APA) | |
| T13OT01177 | Expired | 10/03/2013 | 07/06/2014 | SIGN | 90 DAY BANNER; 10/04/13 - 01/02/14 | |
| T22RW00679 | Final | 02/25/2022 | 05/07/2022 | ROW | BORE 112' TO PLACE 3- 1.25" INNERDUCT. PLACE 1-30X48 HANDHOLE AND INTERCEPT 1 HANDHOLE IMMEDIATELY ADJACENT TO OR DIRECTLY ASSOCIATED WITH A SMALL WIRELESS FACILITY S 7TH AVE IS UNDER A PAVEMENT MORATORIUM, ANY NEW ASPHALT THAT IS DISTURBED WILL REQUIRE A 2" MILL AND OVERLAY FOR 50' IN EACH DIRECTION FROM THE OUTSIDE OF THE CUT FOR ALL EFFECTED TRAVEL LANES. 1. BUS STOP IN THE AREA, CONTACT SUN TRAN, BEA PAULUS AT 520-206-8826 AND/OR CHRISTINA ROCK AT 520-206-8934 24-HOURS PRIOR TO START OF WORK FOR COORDINATION. 2. PLACE "BUSINESS ACCESS" SIGNS APPROPRIATELY. SEVERAL BUSINESSES ALONG ROUTE. 3. INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. 4. PAVEMENT PATCHING IS NECESSARY WHERE PAVEMENT IS CUT. PATCH LIMITS- THE LIMITS OF THE PAVING SHALL BE A MINIMUM OF 1-FT OUTSIDE THE EXCAVATION. 5. POTHOLES SPACED CLOSELY TOGETHER AND WITHIN 8-FT OF EACH OTHER WILL NEED TO BE JOINED TOGETHER BY ONE SURFACE PATCH. 6. BACKFILL WITH CLSM SLURRY OR AGGREGATE BASE COURSE (ABC.) 7. ASPHALTIC CONCRETE USED SHALL BE CITY OF TUCSON MIX NO. 3 OR COT MIX NO. 2 WITH TR-22, INSPECTOR TO ADVISE. 8. REPLACE/ REFRESH ALL STRIPING THAT IS INTERRUPTED BY PATCHES. 9. REPAIR ALL LANDSCAPING DISTURBED. THIS INCLUDES IRRIGATION, PLANTINGS, GROUNDCOVER, AND HARDSCAPE. 10. GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION. 11. MAINTAIN PEDESTRIAN ACCESS 12. MAINTAIN ACCESS TO BUS STOPS AND FOR PEDESTRIAN INGRESS/ EGRESS. 13. IN THE EVENT THAT WEEKEND OR AFTER-HOURS WORK IS INTENDED, CONTACT COT INSPECTION STAFF. IF WEEKEND WORK, MAKE CONTACT 48 HOURS PRIOR TO THE WEEKEND. DAN ROBERTSON- 520-400-6722 OR TOM ADKINS- 520-400-3813 |
Code Enforcement
Parcel Number - 12008625A
Date - 08/18/2026 10:29 a.m.
Total Number Of Code Cases - 6
| Case Number | Case Status | Entered Date | Closed Date | Unit | Type | Description |
|---|---|---|---|---|---|---|
| T07DV04899 | Cancel | 05/30/2007 | N/A | DNR_VIOL | WEEDS IN BACK | |
| T07DV10296 | Complian | 10/03/2007 | N/A | DNR_VIOL | SIGN CODE VIOLATION: ILLEGAL BANNERS. | |
| T10DV07258 | Noverify | 10/14/2010 | N/A | DNR_VIOL | ES referral: Yard full of junk. | |
| T10FR01257 | Complete | 06/25/2010 | N/A | FIREINSP | Elite auto tint. | |
| T12DV01382 | Complian | 02/22/2012 | N/A | DNR_VIOL | SIGN VIOLATION | |
| T99VL01722 | Complian | 06/30/1999 | 10/27/1999 | CODEVIOL | COMPLAINT:WOOD STRUCTURE ATTACHED TO S.END NO PERM |