Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Parcel Search
 
Parcel Attributes
Parcel10709043B
JurisdictionTucson, Pima County
City of Tucson ZoningC-2
Tucson WardWard 3
Tucson Registered NeighborhoodMiracle Manor
Major Street & Route

Gateway Route

Pima County Data Assessor, Recorder, Treasurer, ...
Parcel Map Map
Addresses
Parcel Attributes Issue?

Annexations & Original City Zoning (OCZ)

Date - 08/17/2026 4:06 a.m.
Total Number Of OZC Plans - (1)
Plan Description Annexation Ordinance Effective Date OCZ Ordinance
C9-59-19 North To Roger Rd. And East To Kolb Rd. 1895 04/26/1959 1957

Permits

Parcel Number - 10709043B
Date - 08/17/2026 4:06 a.m.
Total Number Of Permits - (7)
Permit Permit Status Entered Date Expired Date Unit Type Description
T03CM02726 Withdrwn 06/03/2003 N/A COMBO INSTALL:ROLL UP DOOR
T05AN00701 Issued 06/28/2005 N/A #200 ADDRNEW
T05AN00702 Issued 06/28/2005 N/A ADDRNEW
T05BU01769 Final 07/14/2005 03/05/2006 #200 SPKLR FIRE SPKR: ADD 26, RELOCATE 34
T05CM01217 Final 03/18/2005 11/06/2006 COMBO TI:OFFICE
T21RW03446 Final 07/22/2021 04/06/2022 ROW Start at 400 W Mciver Pl.Tie into TEP Pole Head N 300' overlashing 144ct fiber, Continue E 166' and Riser down TEP Pole. Begin Trench/bore Heading E 244' placing 48ct fiber. Continue Trench/Bore Heading N 170' Placing 48ct fiber. Place 4'X4' Pothole and new Cox vault Trench/bore 8' heading E tie into existing vault. ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. OTHER ACTIVITIES IN THE AREA, WILL NEED TO COORDINATE TRAFFIC CONTROL SETUP WITH EXISTING SETUP. BUS STOP IN THE AREA, CONTACT SUN TRAN DISPATCH, AT 520-206-8934 AND/OR BEA PAULUS AT 520-206-8826 AT LEAST 48-BUSINESS HOURS PRIOR TO START OF WORK FOR COORDINATION. 1. BUS STOP IN THE AREA, CONTACT SUN TRAN, BEA PAULUS AT 520-206-8826 AND/OR CHRISTINA ROCK AT 520-206-8934 24-HOURS PRIOR TO START OF WORK FOR COORDINATION. 2. PLACE "BUSINESS ACCESS" SIGNS APPROPRIATELY. SEVERAL BUSINESSES ALONG ROUTE. 3. INGRESS/ EGRESS FOR BUSINESS AND RESIDENTIAL ACCESS SHALL BE MAINTAINED. FIELD ADJUSTMENTS MAY BE REQUIRED. 4. PAVEMENT PATCHING IS NECESSARY WHERE PAVEMENT IS CUT. PATCH LIMITS- THE LIMITS OF THE PAVING SHALL BE A MINIMUM OF 1-FT OUTSIDE THE EXCAVATION. 5. POTHOLES SPACED CLOSELY TOGETHER AND WITHIN 8-FT OF EACH OTHER WILL NEED TO BE JOINED TOGETHER BY ONE SURFACE PATCH. 6. BACKFILL WITH CLSM SLURRY OR AGGREGATE BASE COURSE (ABC.) 7. ASPHALTIC CONCRETE USED SHALL BE CITY OF TUCSON MIX NO. 3 OR COT MIX NO. 2 WITH TR-22, INSPECTOR TO ADVISE. 8. REPLACE/ REFRESH ALL STRIPING THAT IS INTERRUPTED BY PATCHES. 9. REPAIR ALL LANDSCAPING DISTURBED. THIS INCLUDES IRRIGATION, PLANTINGS, GROUNDCOVER, AND HARDSCAPE. 10. GOOD HOUSEKEEPING MEASURES SHALL BE PRACTICED DURING WORK AND CONSTRUCTION. 11. MAINTAIN PEDESTRIAN ACCESS 12. MAINTAIN ACCESS TO BUS STOPS AND FOR PEDESTRIAN INGRESS/ EGRESS. 13. IN THE EVENT THAT WEEKEND OR AFTER-HOURS WORK IS INTENDED, CONTACT COT INSPECTION STAFF. IF WEEKEND WORK, MAKE CONTACT 48 HOURS PRIOR TO THE WEEKEND. DAN ROBERTSON- 520-400-6722 OR TOM ADKINS- 520-400-3813
T21RW04080 Final 09/01/2021 10/10/2021 ROW POTHOLE NEEDED TO COMPELTE LOCATE 2 5X5 BELLHOLES IN BLACKTOP TO POTHOLE GAS LINE. Proof of notification is required at the time of the preconstruction meeting.

Code Enforcement

Parcel Number - 10709043B
Date - 08/17/2026 4:06 a.m.
Total Number Of Code Cases - 1
Case Number Case Status Entered Date Closed Date Unit Type Description
T08FR01214 Field 05/12/2008 N/A FIREINSP Document the need for Central Alarm to decipher the need for medical or fire prior to calling 911. A letter was drafted and signed by manager Janet Curtis stating they will comply with NFPA ch 72 on "separate and distinct" messages.