Inspection History Details
Inspection Status: Passed
Inspection History: TRSP - PIA - Drainage - Pipe Installation/Removal
Permit Number - TR-PIA-1122-00001
Inspection Description - TRSP - PIA - Drainage - Pipe Installation/Removal
Inspection Status - Passed
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/29/2025 | TRSP - PIA - Drainage - Pipe Installation/Removal | Passed | Headwall for triple barrel RCP drainage. Rebar inspection for floor. | |
| 07/30/2025 | TRSP - PIA - Drainage - Pipe Installation/Removal | Re-inspection required | Rescheduled pour due to not having approved mix on site. BF was going to pre-mix on site. | |
| 07/31/2025 | TRSP - PIA - Drainage - Pipe Installation/Removal | Passed | Sample cylinders taken for three barrel drainage head wall base | |
| 08/06/2025 | TRSP - PIA - Drainage - Pipe Installation/Removal | Passed | Rebar inspection for headwall was done on site at triple barrel drainage along Alvernon just S of Los Reales. #4 rebar was used, spacing was at 8" for 4 foot header wall. One 90 degree bend in the structure. All rebar was in good shape and tied together with metal wire to keep in place and secure. | |
| 08/13/2025 | TRSP - PIA - Drainage - Pipe Installation/Removal | Passed | Epoxy inspection on Fresno Valves installed on the south side of the RCP pipes. Three in total. Have been installed and functioning properly. | |
| 11/04/2025 | TRSP - PIA - Drainage - Pipe Installation/Removal | Canceled |