Parcel: 12618111E


Addresses:

3925 E 22ND ST


Inspection Status: Not Ready

Inspection History: For trash and recycling enclosures

Permit Number - TD-DEV-0723-00310

Inspection Description - For trash and recycling enclosures

Inspection Status - Not Ready

Date Description Inspector Results Comments
12/10/2025 For trash and recycling enclosures Not Ready 12/10/25
I talked to mason and superintendent about the specifics of TSM double Refuse enclosure and inspections needed. However Rebar reinforcing not in place yet in footer.
12/11/2025 For trash and recycling enclosures Re-inspection required (with fee) Bollards not in place for pour. 2nd not ready.
12/12/2025 For trash and recycling enclosures Partial Pass 12/12/25
Footer dimensions and reinforcing correct. Bollard footers correct. Footer okay to pour.
Request inspection for pregrout when wall is built per plan and ready with bond beam at top. Use ladders horizontal reinforcement at 16" oc.
For trash and recycling enclosures Scheduled